TROUBLESHOOTING
F A U L T
Water drips out
when moving unit
Unit does not
operate
Blower wheel not
turning
Unit operating,
but room not dry
Unit collects too
little water
If the problem you are experiencing is not listed here, call your local distributor or contact
our Service Department toll-free at 800-932-3030 for further assistance.
SPECIFICATIONS
Model
Weight
Dimensions
(H × D × W)
Power
Water removal AHAM
(80°F/60% RH)
Water removal low grain
(80°F/20% RH)
Process air (max.)
Noise level (avg.)
Air filter
Drain hose
Power cord
Construction
Safety
Specifications are subject to change without notice. Some values
may be approximate.
*Fan speed varies automatically for optimized performance.
07-01776H F412-115V
C A U S E
Unit was unplugged before
purging was complete.
Unit not switched on.
No power to machine.
Obstructed blower.
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Room air is dry.
Room temperature is too low.
HAF filter is full.
Heat exchange block and/or
coils are clogged.
LGR 7000XLi (F412)
107 lbs. | 49 kg
33.5 × 20 × 20 in. | 85 × 51 × 51 cm
8.3 amps, 115V
130 pts. | 61.5 liters / day
17 pts. | 8 liters / day
325 CFM* ductable floor-level outlet.
62 dB
3M™ HAF filter
Part no. F368 (24 pack)
40 ft. | 12.2 m
25 ft. | 7.6 m
Rotomolded shell
ETL certified CSA 22.2 no. 92
S O L U T I O N
Purge unit before moving. See "At the End of the Job," p. 5.
Switch unit on.
Plug in unit; check power cord connection at wall outlet and at
base of unit.
Remove duct ring and grill and remove obstruction. Replace
duct ring and grill.
Allow more time for drying.
Increase air movement with air movers.
Seal off area to reduce infiltration.
Confirm humidity level with hygrometer.
Increase room temperature.
Check filter. Clean or replace as necessary.
Check heat exchange block and coils. Clean as necessary.
Warranty information is available at www.dri-eaz.com.
Be sure to visit warranty.drieaz.com and register your
purchase. Your registration will help us provide you with
updated product information as needed.
For proper disposal, this unit should be taken to a
recycler licensed to process refrigeration equipment.
11