Troubleshooting Guide - Guardian AC5350 Serie Instrucciones De Uso Y Cuidados

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLING & REMOVING UV-C BULB
UV Bulb Replacement Indicator: The UV light on the display will flash when its time
to replace the UV bulb.
2. Remove the
1. Turn off and unplug unit.
combination filter.
Press the lock and release
button and remove the
rear cover from the unit.
4. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and pulling
the bulb straight out of the unit.
Bulb is NOT visible
until the UV-C METAL
SHIELD has been
removed.
5. The UV-C Bulb is reinstalled by sliding it, horizontally, back into the slots at the top of the unit.
E-8
3. Use a Philips head
screwdriver to remove
2 screws and detach the
UV-C Metal Shield.
NOTE: Do NOT stick any foreign objects or your fingers inside of the unit.
CAUTION: Do NOT use gasoline, benzine, thinner, harsh cleaners, etc. on and/or in
the unit while cleaning as they will damage the product.
NEVER use alcohol or other solvents.

TROUBLESHOOTING GUIDE

PROBLEM
Unit does not operate.
Check that the unit is plugged in.
Check that filter is in place.
Confirm that filter is Genuine Replacement Filter
Call Customer Service.
Unit shuts off unexpectedly.
Check that unit is plugged into a working electrical outlet.
Check that filter is firmly in place.
Check that the Rear Cover is latched firmly in place.
Call Customer Service.
No air circulating from unit.
Unplug unit. Check Pre-/Carbon and filters.
Clean Pre-/Carbon Filter if necessary.
Replace filter if necessary.
Increase in noise level.
Make sure the filters are clean. Replace if necessary.
Control buttons "beep"
To shut off the "beeping" sound when buttons are pushed.
when pushed.
1. Press and hold the TIMER and UV buttons for 3 seconds.
(AC5350 Series)
2. Select ON/OFF.
'Beeping' will automatically be reset to ON when the
unit is unplugged.
Red light is flashing.
Replace filter and reset system.
Blue ring on product
Replace bulb and reset system.
is flashing.
What is CADR?
CADR stands for "Clean Air Delivery Rate," which indicates the volume of filtered air delivered by
an air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing
fine particles from things like tobacco smoke and plant pollens from the room.
Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer
to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.
Refer to website for individual model CADR numbers.
SOLUTION
E-9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ac5300

Tabla de contenido