2.
INSTALLATION
2.1
Connection to toilet
FEKALIFT 100-A : the system must be connected to a toilet with horizontal outlet, as indicated in
fig.B page 61
FEKALIFT 200-A : the system must be connected to a toilet with horizontal outlet, closing the unused
lower side inlet, as indicated in fig.E-F page 61
2.2
Connection to discharge
Push the large end of the bend into the outlet of the appliance, turn it in the desired direction and fix it with a
clamp. For FEKALIFT 100-A push also mouth B onto the other end and fix it too with a clamp. Then
connect the discharge to the pump outlet and fix it with a clamp (fig. C-G page 61).
3.
ELECTRICAL CONNECTION
Attention: always respect the safety regulations!
The electrical connections must be made after assembly of the system!
Electrical installation must be carried out by an expert, authorised electrician, who takes on all
–
responsibility.
Connect the plug to a 10 – 16A 2-pole EARTHED socket.
–
–
The socket must supply only the power to the system; for FEKALIFT 100-A it must be connected to an
automatic safety switch and for FEKALIFT 200-A to a highly sensitive differential switch calibrated at
30 mA.
4.
COMMISSIONING
Connect to the power socket.
–
Flush the toilet once; the system must start automatically, model FEKALIFT 100-A must work within a
–
period of 10 max. 30 sec. and FEKALIFT 200-A within a period of 5 max. 30 sec. If the start time
exceeds 35 sec., check that the discharge pipe is not crushed or blocked.
After this operation the toilet can be used just like an ordinary one.
5.
MAINTENANCE AND CLEANING
Repairs to the motor or the electric components may be carried out only by
–
specialised and authorised personnel.
–
All repair and maintenance work must be carried out only after having disconnected
the appliance from the power supply mains.
In most cases any malfunctions are due to minimum causes which you can usually
–
solve yourself. For all other problems apply to an authorised repair centre (follow the
instructions in the TROUBLESHOOTING table).
5.1
Removing the grinder from the toilet pan
–
Disconnect the appliance from the power supply mains.
–
Turn off the corner supply tap and remove most of the water from the siphon of the toilet basin.
–
Disconnect the delivery pipe and the supply pipes.
–
Remove the appliance from the toilet.
Turn the electric power back on only after having concluded reassembly of the system.
5.2
Foreign bodies
If a foreign body gets into the Fekalift through the toilet, the problem can be solved easily without having to
contact service personnel: first of all take the plug out of the socket; remove the foreign body from the
toilet inlet with the aid of a screwdriver or a piece of wire. Take care not to make a hole in the pump inlet!
The blades are very sharp, NEVER PUT YOUR HAND INTO THE APPLIANCE!
ENGLISH
7