Descargar Imprimir esta página

DAB DTRON2 35/90 M Instrucciones De Instalación Y Mantenimiento página 17

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 42
2
INSTALLATION
Before starting up the pump, check that:
The voltage and frequency on the pump's technical data plate correspond to the values of the power supply system.
The pump's power cable or the pump is not damaged.
The electrical connection must be made in a dry place, far from any possible flooding.
The electrical system is provided with a residual-current circuit breaker with I ∆n ≤ 30 mA and that the earth system is efficient.
Any extension cables comply with the regulations in force.
2.1
Mechanical Installation
Install the pump in a location that is not exposed to freezing.
When the pump remains inactive at a temperature lower than 0°C, it is necessary to ensure that there is no water residue which
could freeze and damage it.
Hang the pump by passing the rope through the hole provided (see figure 5). Do not hang the pump by the handle.
Do not install check valves near the pump delivery (distance less than 1 metre (3.28ft)). The pump already has a built-in check
valve on delivery.
The DTRON2 pumps already contain a small expansion tank, calibrated for water hammer and small leaks.
In order to reduce the number of pump starts, an auxiliary tank (Figure 6, A) with a capacity of 2 litres can be installed.
If you want to install an additional non return valve (Figure 6, B), it is recommended to position it downstream from the auxiliary tank.
Do not subject the motor to excessive starts per hour. It is strictly recommended not to exceed 60 starts per hour.
It is advisable to use pipes having a minimum diameter of 1'', to avoid the decrease of pump performance.
Fig.4 Data plate
ENGLISH
Pos.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
11
Description
Description
Revision
Year
Week
Serial number
Maximum liquid temperature
Use
Flow rate
Maximum head
Minimum head
Insulation class
Degree of protection
Submersibility
Rated voltage
Ampere
P1
P2 HP
P2 kW
Frequency
Condenser capacity
Voltage
Rated number of revolutions
Logos
Pump code

Publicidad

loading

Este manual también es adecuado para:

Dtron2 35/90Dtron2 45/90Dtron2 x 45/90Dtron2 35/12060195238