position «0» and unplug it.
EN
• If you feel eye or other pain during the light exposure session, stop using the LUMINESCENCE lamp
immediately and consult your doctor.
MAINTENANCE AND STORAGE
Cleaning:
• Unplug the device and let it cool down.
• Use a cloth or damp sponge to clean the exterior surface of the lamp.
• Never use a scrubbing brush, abrasive products or aggressive detergents such as acetone or white
spirit to clean the device.
REPLACING THE TUBES
The device contains no parts needing replacement other than the tubes. The tubes are expected to
last for approximately 8000 hours of use (which corresponds to several years of normal use). The
tubes must be replaced by similar ones.
To replace the tubes, please follow the following instructions:
- Using a screwdriver (not supplied), release the 3 screws located at the back of the product (see
Fig. 3).
- Then remove the reflector screen as illustrated in Figs. 4 & 5.
- Then, pull back the fixing clip and remove it as shown in Figs. 6 & 7.
- Once you have replaced the tube, replace the reflective screen before using the LUMINESCENCE
lamp.
TECHNICAL SPECIFICATIONS
Voltage: 220-240V
Frequency: 50Hz
Power consumption: 48W
6