Separate heating and cooling transformers
Single stage heat pump with auxiliary heat (electric or dual fuel)
Two stage heat pump with auxiliary heat (electric or dual fuel)
C
Common wire (optional)
W
Heat relay
G
Fan relay
Y
Compressor contactor (stage 1)
R
Power
Rc
Power
C
Common wire (optional)
AUX
Auxiliary/Emergency heat
O/B
Reversing valve
G
Fan relay
Y
Compressor contactor (stage 1)
R
Power
C
Common wire (optional)
AUX
Auxiliary/Emergency heat
O/B
Reversing valve
Y2
Compressor contactor (stage 2)
G
Fan relay
Y
Compressor contactor (stage 1)
R
Power
9
Notes
• Thermostat C wire
is optional for this
application. C wire
required if Homekit
is used.
• Set the R Jumper
Switch on the wall
plate to R & Rc
Notes
• Thermostat C wire
is optional for this
application. C wire
required if Homekit
is used.
• Set the R Jumper
Switch on the wall
plate to R
Notes
• Thermostat C wire
is optional for this
application. C wire
required if Homekit
is used.
• Set the R Jumper
Switch on the wall
plate to R