en
ENGLISH
8. Tips and Tricks
To saw tight curves: Use narrow saw blades.
Sawing metal: To increase the life of the saw
blades, apply cooling lubricant (cooling lubricant
rod 6.23443) along the cutting line.
9. Maintenance
On a regular basis, use compressed air to blow out
the machine through the rear ventilation slots.
Regularly clean the saw blade quick-clamping
device (2) and blow out with compressed air. Do not
oil or grease.
10. Accessories
Use only genuine Metabo accessories.
See page 4.
Use only accessories which fulfil the requirements
and specifications listed in these operating
instructions.
A) Comprehensive range of saw blades for
a wide variety of materials and use cases
For complete range of accessories, see
www.metabo.com or the main catalogue.
11. Repairs
Repairs to electrical tools must be carried out
by qualified electricians ONLY!
Contact your local Metabo representative if you
have Metabo power tools requiring repairs. For
addresses see www.metabo.com.
You can download a list of spare parts from
www.metabo.com.
12. Environmental Protection
Observe national regulations on environmentally
compatible disposal and on the recycling of disused
machines, packaging and accessories.
Only for EU countries: Never dispose of
power tools in your household waste! In
accordance with European Guideline
2002/96/EC on used electronic and electric
equipment and its implementation in national legal
systems, used power tools must be collected sepa-
rately and handed in for environmentally compatible
recycling.
13. Technical Specifications
Explanatory notes on the specifications on page 3.
Changes due to technological progress reserved.
P
= Nominal power input
1
P
= Power output
2
I
= Current
n
= Stroke rate at idle speed
0
s
= Stroke length
10
m
= Weight without mains cable
Measured values determined in conformity with
EN 60745.
Machine in protection class II
~
AC Power
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
Emission values
These values make it possible to assess the
emissions from the power tool and to compare
different power tools. Depending on the operating
conditions, the condition of the power tool or the
accessories, the actual load may be higher or lower.
For assessment purposes, please allow for breaks
and periods when the load is lower. Based on the
adjusted estimates, arrange protective measures
for the user e.g. organisational measures.
Vibration total value (vector sum of three directions)
determined in accordance with EN 60745:
a
= Vibration emission value
h, CW
(Sawing in wood)
K
= Unsafe (vibration)
h, CW
Typical A-effective perceived sound levels:
L
= Sound-pressure level
pA
L
= Acoustic power level
WA
K
, K
= Uncertainty
pA
WA
During operation the noise level can exceed
80 dB(A).
Wear ear protectors!