Specification
250V AC (cosø =0.4): 3A max
DC 150W max, 220V DC max
Display
30V DC: 5A max
Black on green STN LCD, with
5A resistive load 100,000 operations
yellow/green LED backlight.
2A resistive load 1,000,000 operations
Program Storage
Reaction time: <20ms.
Erase/write cycles:1,000,000
Supply (see Connections)
Life: 40 years min
Count Range
94 to 240V AC ± 10% 50/60Hz
VA Rating 4VA
0 to 999999
Count Pre-scaler
or 12 to 24VDC ± 10%
Multiplier 0.00250 to 9.99999
typical current 100mA DC (max)
Installation Category (IEC 664)
Divider 1 to 99999
Timing Range - see page 7
Overvoltage category II
Timing Acuracy ± 0.3%
(Pollution degree 2 )
Inputs (see Inputs)
Operating temperature
High Speed: 10kHz max (electronic)
-10°C to +60°C
Storage temperature
Duty cycle: 60:40 max
Low Speed: 30Hz max (contact closure)
-20°C to +70°C
External Reset response time
Environmental protection
Max 2mSec
IP65 (panel mounting) using the sealing
Relay Contacts (see Relays)
gasket supplied (without Screw-fixed
UL Ratings
bezel). If the seal is removed, it must be
AC 250V max, DC 125V max
replaced with a new one.
250V AC:
1
HP max
/
See page 39 for cut-out dimensions
6
Altitude
30V DC: 5A max
General ratings
Up to 2000m
AC 1250VA max, 300V AC max
Relative Humidity
80% max up to 31°C, decreasing to 50%
250V AC (cosø =1): 5A max
max at 40°C
The Front Panel
Relay State
(showing the state of the
normally open contact)
Digit 6
Reset
The front panel buttons are used to program the counter and to display and set the P1
preset. All the buttons can be disabled by the Keyboard Inhibit input. (see Programming
on page 6).
P1 Preset
The P1 preset can be set at any time. The minimum value possible is 000001. P1 must
be greater than any multiplying prescaler value, or the unit may not operate correctly.
Count/
Time
P1
Press SEL, then use the Digit buttons to change P1. The display will flash. Press SEL
again to accept the new value. If SEL is not pressed within 30 seconds of the last
change, P1 will revert to the original value.
In Reset to Zero mode, the change will be accepted immediately.
In Reset to P1 mode, the change will not be accepted until after a Reset.
2
Count or Time
P1 Preset
Multiplying Prescaler
Dividing Prescaler
Digit 1
Select
Program