Monitor output
Alignment outdoor (2) Alignment indoor (3)
voltage (1)
60-250 mV
Poor. Re-adjust (4)
less than 60 mV
Note: Table shows voltage under non-attenuation sheet condition.
Testing the unit:
Test monthly. Walk in front of the receiver
and see if the Alarm LED lights when the beam is blocked.
Confirm the relay function by observing the status light on the
control panel.
Maintaining the unit:
The units are virtually maintenance free
except for units located in dusty or dirty locations. Clean dirty
units with a damp cloth as necessary.
Adjusting the response time
See Figure 15.
Response time (sec.). 1. Response 0.05 sec: running at full
speed. 2. Response 0.3 sec: walking quickly; 3. Response 0.7
sec: walking.
This feature is used to modify the response time of the beam to
best suit the application. The unit cannot detect objects that
move faster than the set response time. However, increasing
the set response time may result in the unit not detecting
people.
Changing beam frequency
Change the beam frequency to prevent cross talk or bypass of
beams. This can occur with line or 2-stacked protection.
Figure 16:
Setting the beam channel.
1.
Set the transmitter and receiver to the same channel. The
units do not provide protection if set to different channels.
2.
See figure 16 to set the beam channel when installing two
or more units in a line or 2-stacked protection.
protection;
B:
2-stacked protection;
protection.
Note:
When multi-stacked or line protection is used, it is
recommended that beam alignment is done with a tester to
improve reliability as well using the beam frequency change-
over function. When multi-stacked protection is used, both
upper and lower sensors should have the same model
numbers.
External dimensions
See Figure 17.
Figure 17 description
1
Knockout
2
Wire lead
Troubleshooting
Problem
Possible cause
Operation
No power supply.
LED does
not light.
Bad wiring connection or
broken wire (short).
6 / 26
Good
Poor. Re-adjust (4)
A:
Line
C.
Line and 2-stacked
Remedy
Turn on the power.
Check and correct the wiring.
Problem
Possible cause
Alarm LED
No power supply.
does not
light when
Poor wiring connection or
the beam is
broken wire (short).
interrupted.
Beam is reflected on to
another object and sent
to the receiver.
Two beams are not
broken simultaneously.
The beam interruption
time is shorter than the
set response time.
Beam alignment is out.
Alarm LED
continues
Shading object between
to light.
the transmitter and the
receiver.
Unit optics are dirty.
Frequency channel is not
compatible between the
transmitter and the
receiver.
Intermittent
Bad wiring connection.
alarms
Change of supply
voltage.
Shading object between
transmitter and the
receiver.
A large electrical noise
source, such as a power
machine, is located near
the transmitter and the
receiver.
Unstable installation of
transmitter and receiver.
Dirty transmitter or
receiver optics.
Incorrect alignment.
Small animals may be
passing through the two
beams.
Specifications
Model
PB501
Detection
Simultaneous interruption of 2 beams
system
Infrared beam LED pulsed beam, double modulation
Outdoor 20 m
Protection
distance
Indoor 40 m
Response
0.05-0.7 seconds variable (variable at pot)
time
Power supply
12-30 VDC (non polarity)
Current
55 mA or less
consumption
Remedy
Turn on the power.
Check and correct the
wiring.
Remove the reflecting
object or change the beam
direction.
Interrupt two beams
simultaneously.
Adjust the beam response
time.
Check and adjust again.
Remove the shading
objects.
Clean the optics with a soft
cloth.
Readjust to the same
channel.
Check again.
Stabilize supply voltage.
Remove the shading object.
Change location of the
installation.
Stabilize.
Clean the optics with a soft
cloth.
Check and adjust again.
Increase the response time.
(impossible in a location
where the intruder can run
at full speed.)
PB511
PB521
Outdoor 40 m
Outdoor 60 m
Indoor 80 m
Indoor 120 m
75 mA or less
80 mA or less