Battery Service; Cleaning Fuel Sediment Cup - Honeywell HW7500E Manual Del Propietário

Portable electrical generator
Ocultar thumbs Ver también para HW7500E:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Battery Service

To ensure the battery remains charged, it is recom-
mended that the generator is started every three months.
If the unit is stored for more than a year without running, a
battery charger may be required to recharge the generator
battery.
Recommended Battery Replacement:
Xtreme
XTAX14AHL-BS
Yuasa
12N14-3A
TABLE 4. Replacement Batteries
To replace battery:
Loosen and remove nuts on retaining plate; slide
1.
retaining plate off support rods.
FIGURE 46: Electric Start Battery—Remove Retaining Plate
2.
Tip battery slightly forward.
Disconnect the black negative (-) battery lead remov-
3.
ing the boot, bolt, and nut.
FIGURE 47: Electric Start Battery—Lead Connection
4.
Disconnect the red positive (+) battery lead removing
the boot, bolt, and nut.
5.
Remove the battery.
NOTE:
Dispose of used battery according to guidelines estab-
lished by your local or state government.
6.
Place the new battery in the generator frame.
Connect the red positive (+) battery lead to the posi-
7.
tive (+) post on the battery; install bolt, nut, and boot.
8.
Connect the black negative (-) battery lead to the neg-
ative (-) post on the battery; install bolt, nut, and boot.
9.
Reinstall retaining plate; tighten bolts and nuts.
HW7500E/HW7500EL Portable Electrical Generator Owner's Manual

Cleaning Fuel Sediment Cup

The sediment cup helps prevent fuel tank residue from
entering the carburetor.
Clean fuel sediment cup at the intervals specified in
Table 2.
To clean fuel sediment cup, you will need:
‰ 10 mm box wrench
‰ 14 mm open end wrench
‰ Household soap and water
‰ Clean, dry cloth
To clean fuel sediment cup:
Stop engine if it is running. Allow to completely cool.
1.
Place the generator on a flat, level surface.
2.
Turn fuel shut-off valve to OFF position.
3.
4.
While holding the fitting above the fuel shut-off valve
with a 14 mm open end wrench, remove the fuel sedi-
ment cup assembly (sediment cup, o-ring, and fuel
screen) using a 10 mm box wrench.
FIGURE 48: Fuel Sediment Cup Assembly Removal
Clean fuel screen (A), o-ring (B), and sediment cup
5.
(C) with soap and water.
FIGURE 49: Fuel Sediment Cup Assembly
Rinse parts thoroughly with water.
6.
Wipe pieces clean with clean, dry cloth.
7.
Reinstall sediment cup, o-ring, and fuel filter.
8.
9.
Turn fuel shut-off valve to ON position.
Start generator and check for leaks.
10.
www.honeywellgenerators.com
Battery Service
A
B
C
27

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Hw7500el

Tabla de contenido