Warnings & Cautions
The Intella-Stop™ Xtreme has built in troubleshooting/
diagnostic features.
Situation: screen flashes Warning! Open Ground
Probable Cause: Trailer is connected and
Intella-Stop™ Xtreme loses connection to battery ground.
Situation: screen flashes Warning! Overload
Probable Cause: Intella-Stop™ Xtreme detects an
excessive current overload condition during operation.
Situation: screen flashes Warning! Output Shorted
Probable Cause:
1. Detects brake output wire shorted to ground.
Short during idle condition.
2. Use of some test lights or testers can cause this
problem.
Situation: screen flashes Caution! Power Loss
Probable Cause: Power to Intella-Stop™ Xtreme
interrupted during braking or stop lamp active while
connecting power to the trailer brake control.
Situation: screen flashes No Trailer Connection!
Probable Cause:
1. Trailer not connected to tow vehicle.
2. Trailer connected with open circuit on brake line.
3. Trailer connector disconnected or corroded.
4. Loss of trailer brake magnet ground.
10
ALTERNATING SCREENS