Maytag MGC4430BDB Manual De Instalación página 10

Superficies para cocinar de gas selladas 30” y 36”
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Burner Performance
CAUTION:
Never cover control knobs or surrounding
control surface with utensils, towels, or other objects.
Never obstruct free air passage past the control knobs.
The knob openings have been sized to properly control air
entry to the interior of the appliance during operation.
This appliance has no air shutters. Primary air
adjustments are unnecessary. The burners are designed
to provide optimum aeration for all gases without air
5 BURNER MODEL (36" Wide)
36" Cooktop
INPUT RATES - NATURAL GAS / LP GAS (BTU/HR)
BURNER LOCATION
Right Front
Right Rear
Left Front
Left Rear
Center
FIGURE 15
Hi
12,500 / 10,500
1300 / 1300
9,200 / 9,100
1300 / 1300
9,200 / 9,100
1300 / 1300
10,500 / 9,100
1300 / 1300
9,200 / 9,100
1300 / 1300
High Altitude Notice
The specified gas burner ratings typically apply to
elevations up to 2000 feet. For higher altitudes, the rates
may need to be reduced to achieve satisfactory operation.
A local certified gas servicer will be able to advise if a
reduction is necessary.
shutters. When operating properly, burners should
produce clearly defined, even blue flames. If the flames
have yellow tips or are hazy and otherwise appear to
have insufficient air, obtain the services of a qualified
service technician. Some yellow tipping on LP gas is
normal.
Specified input rates are as shown in figures 15 and 16
below.
4 BURNER MODEL (30" Wide)
30" Cooktop
INPUT RATES - NATURAL GAS / LP GAS (BTU/HR)
Lo
BURNER LOCATION
Right Front
Right Rear
Left Front
Left Rear
Center
FIGURE 16
Hi
12,500 / 10,500
1300 / 1300
9,200 / 9,100
1300 / 1300
9,200 / 9,100
1300 / 1300
9,200 / 9,100
1300 / 1300
- - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - -
Lo

Publicidad

Tabla de contenido
loading

Tabla de contenido