Testing Diodes (
• Slide the function switch to the /
Note: The measurement mode defaults to Ohms ( ).
• Press the /
display should show the
• Ensure the circuit is de-energized to prevent inaccurate readings.
• Apply the red test lead to the anode of the diode and the black lead to the
cathode (gray ring). Verify the forward voltage drop is about 0.6V for silicone.
• Reverse the test lead connections. Verify an "OL" reading in the display.
• If the diode is shorted, 0mV will be displayed.
• If the diode is opened, "OL" will be displayed both directions.
Note: Audible indication occurs at <0.25V.

Battery Replacement:

• Ensure test leads are disconnected from any
circuit or components.
• Remove the screw from the battery cover.
• Remove the battery cover.
• Replace batteries with two 1.5V button cell
batteries.
• Assemble the back case on the meter and re-tighten the screw.
Maintenance:
• Clean the case with a damp cloth and mild detergent. Do not use abrasives or
solvents.

Service, and Replacement Parts:

No user-serviceable parts.
For replacement parts or to inquire about service information contact
IDEAL INDUSTRIES, INC. at 1-877-201-9005 or visit our website
www.testersandmeters.com.
/
):
/