Optional
Temperature sensor: PT100
-
1.4__WARNINGS
Keep the hydraulic section clean where the pH and Redox probes are located.
1.5__MATERIAL REQUIRED FOR INSTALLATION
2___INSTALLATION
Disconnect the power supply before carrying out the installation of the system or any maintenance on it.
Check that the power supply voltage coincides with that indicated on the tag placed on the measurement tool.
Lack of respect for any of the instructions in this manual could cause damage to people or things or incorrect
operation and damage to the parts.
FOR THE INSTALLATION, PROCEED AS FOLLOWS:
-
Position the panel on the wall at a height from the ground that makes it easy to access both the lower and the
upper part of the panel.
-
Note The panel must be positioned on a level and if possible straight. Leave the floor area free in order to
allow easy access to the panel.
Connect the water inlet to a tap that guarantees an uninterrupted water flow rate of between 40 and 60 l/h at a
-
pressure equal to the outlet back pressure + 0.5 bar; it is recommended that this pressure does not exceed 6
bar.
The flow rate must remain constant; any variations can cause measurement errors of 1.5%/ l/h.
-
For lack of power supply, the delivery hose can be emptied; it is recommended to insert a non-return valve at
-
the inlet. Hence, the emptying of the electrode-holder tank by siphoning is prevented, a situation that damages
the pH measurement electrode.
Connect the outlet to a water recovery point with a maximum back pressure of 5 bar.
-
TANK INSTALLATION
Do not position the tanks containing chemical substances under the CLOR TOP; the fumes emitted cause
deterioration of the equipment. The recommended distance is a MINIMUM of 2 m.
NOTE: For calibrating the probes and the connection of the dosing pumps and their use, please see the
INSTALLER INSTRUCTION MANUAL of the measurement system.
KONTROL 40 pH/Redox
Cod. 0000136989
rev. 1.0