Longopac ® Replacement; At The End Of A Cleaning Session; Tightness Inspection; Wiring Diagrams - Blastrac BDC-22-110V Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Instruction manual BDC-22-110V
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container. Use
gloves that provide ANSI/ISEA Level "2" protection.
If necessary contact the manufacturer's Service Center.
Longopac
replacement
®
Prepare the bag holder with the inside part upwards and
insert the Longopac inside the groove on it. Pull off the
Longopac inner end for at least 250 mm, put the strap
around the support as shown in the figure, tighten it by
leaving free the excess part of the inner end pulled off
previously. Properly arrange the excess Longopac inside
the groove (1).
Pull off the Longopac outer end, turn it down and close it
with the proper band (2-3).
Draw near the bag holder to be placed under the hopper
cone, insert the pins into the slots and turn the system to
lock it at the upper cylinder (4).
Pull down the bag closed by the band and lay it on the tray.
Then, by means of the 2
end (250 mm-long), which have been previously removed,
above the gasket on the hopper (5).
Take care not to raise dust when this operation
is carried out. Wear an N100 (P3) mask and other
protective clothing plus protective gloves (PPE/DPI)
suited to the hazardous nature of the dust collected;
refer to the laws in force.
I
Reassemble with care to avoid trapping your hands
US
between the vacuum unit and the container. Use
gloves that provide ANSI/ISEA Level "2" protection.
If necessary contact the manufacturer's Service Center.

At the end of a cleaning session

Turn off the vacuum cleaner and remove the plug from
the socket.
Wind the connection cable.
Clean the vacuum cleaner as described in the
"Maintenance, cleaning and decontamination" paragraph.
Store the device in a dry place, out of reach of unauthorized
people.
Lock the caster brakes (6, Fig. 1).
Shut the inlet with the appropriate plug (4, Fig. 1) when the
vacuum cleaner is transported or not being used.
WARNING!
Figure 10
supplied belt, fasten the inner
nd
WARNING!
WARNING!

Tightness inspection

Hoses check
Make sure the connecting hoses (Fig. 11) are in a good
condition and correctly fixed.
If the hoses are damaged, broken or badly connected to the
unions, they must be replaced.
When sticky materials are collected, check for possible clogging
along the hose, in the inlet and on the baffle plate inside the
filtering chamber.
To clean, scrape the inlet (2, Fig. 11) from the outside to remove
deposits.
Hopper gasket check
Ensure that the Longopac
®
Fig. 12). The gasket must be replaced if it is torn, cut, etc...
Clapet gasket check
Replace the gasket (1, Fig. 12) if it is not tight, or if it is torn,
cut, etc.

Wiring diagrams

Figure 13
Item
Type
Q1
4083901814
Q2
4083901814
www.blastrac.com ‒ info@blastrac.com
10/16
bag is tight with the gasket (2,
Description
Qty
Switch 2 pole
Switch 2 pole
1
1

Publicidad

Tabla de contenido
loading

Tabla de contenido