NightStick XPR-5572 Manual De Instrucciones página 3

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Image 15
degree angle being certain that the base of the light rests on the base contour of the
charger. (Image 12)
y While holding the inserted side of the light against the back of the charger's contour,
fi rmly press straight back on the opposite side of the light (allowing the edge to slide
around the contour of the charger) until it slips past the Spring-loaded Gripper and snaps
into the charger. (Image 13)
WARNING: Attempting to push the Angle Light straight into the charger or from
an angle above or below, could result in damage to the charger and should not
be attempted.
Confi rmation of proper installation can be seen in the LED Charge Indicator Light.
When the Angle Light is properly installed in the charger, and power is being supplied by
the Nightstick AC or DC Power Supply, the LED Charge Indicator Light on the charger
will light up constant RED indicating that the unit is being charged. (Image 14)
REMOVING THE ANGLE LIGHT FROM THE CHARGER
y While positioned in front of the charger, grasp the Angle Light around the bezel and
twist it in either a clockwise or counter-clockwise direction. (Image 15)
y This action will cause the side of the light to disengage from the charger and slip past
the Spring-loaded Gripper. (Image 16)
y While maintaining an approximate 45 degree angle to the light, pull the light straight
away from the charger. (Image 17)
y The light has now been safely removed from the charger and is ready to use.
CHARGING THE ANGLE LIGHT
WARNING: Use only the supplied Charger, Lithium-ion Rechargeable Battery Pack
and AC or DC Power Supply for charging. Do not attempt to charge this light with
non-rechargeable or rechargeable AA batteries installed.
y The time required to charge the Angle Light is conditional on the remaining charge
left in the Lithium-ion Rechargeable Battery Pack at the time of charging. The maximum
charge time required is approximately 6 hours.
y Fully charge the Lithium-ion Rechargeable Battery Pack before the fi rst use, or if the
Lithium-ion Rechargeable Battery Pack has been unused for several months.
y Install the Angle Light into the charger using the exact method described in this
Instruction Manual above ("PLACING THE ANGLE LIGHT INTO THE CHARGER").
WARNING: Failure to do so could damage the charger and/or the light.
y When the Angle Light is properly seated in the charger, the LED Charge Indicator
light will turn solid RED indicating that the Lithium-ion Rechargeable Battery Pack
is charging (Image 14). The Lithium-ion Rechargeable Battery Pack is fully charged
when the LED Charge Indicator light turns GREEN.
y The Lithium-ion Rechargeable Battery Pack does not have any Recharge Memory
Effect, therefore placing the Angle Light in the charger prior to full depletion of the
battery does not adversely affect the battery life. The Angle Light can be kept in the
charger indefi nitely without any negative impact on the battery or the battery life.
OPERATION
THE XPR-5572 HAS EIGHT SEPARATE LIGHTING MODES:
y High-brightness Flashlight
y Medium-brightness Flashlight
y Survival-mode Flashlight
y Flashlight Strobe
y High-brightness Floodlight
y Medium-brightness Floodlight
y Survival-mode Floodlight
y Dual-Light (both the Flashlight and Floodlight on at the same time)
Flashlight Modes
To activate the Flashlight, press and release the Flashlight Switch (Image 18). The
default mode will be High-brightness. To select the brightness level for the Flashlight,
press and hold the Flashlight Switch. The fl ashlight will cycle from high to medium to
Survival and then back up again at a rate of approximately one mode per second. The
light will continue to cycle up and down through the various modes as long as the switch
is held down. When the desired brightness level is reached, simply release the Flashlight
Switch, and the light will remain in that brightness mode. To turn the Flashlight off, press
and release the Flashlight Switch one more time.
Strobe
To activate the Strobe, double click the Flashlight Switch (Image 18). To turn the
Strobe off, press and release the Flashlight Switch one more time.
Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • 1-800-233-2155 • 1-469-326-9400 • www.nightstick.com
Image 16
Image 17
Floodlight Modes
To activate the Floodlight, press and release the Floodlight Switch (Image 18). The
default mode will be High-brightness. To select the brightness level for the Floodlight,
press and hold the Floodlight Switch. The fl oodlight will cycle from high to medium to
Survival and then back up again at a rate of approximately one mode per second. The
light will continue to cycle up and down through the various modes as long as the switch
is held down. When the desired brightness level is reached, simply release the Floodlight
Image 18
mode and go back to either Flashlight or Floodlight mode simply by pressing the switch
for the mode that they wish to turn off. To turn both lights off, simply press each of the
switches independently.
WARRANTY
LIMITED LIFETIME WARRANTY
Bayco Products, Inc. warrants this product to be free from defects in workmanship
and materials for the original purchaser's lifetime. The Limited Lifetime Warranty includes
the LEDs, housing and lenses. Rechargeable batteries, chargers, switches, electronics
and included accessories are warranted for a period of two years with proof of purchase.
Normal wear and failures which are caused by accidents, misuse, abuse, faulty installation
and lightning damage are excluded.
We will repair or replace this product should we determine it to be defective. This
is the only warranty, expressed or implied, including any warranty of merchantability or
fi tness for a particular purpose.
For a complete copy of the warranty, go to www.nightstick.com/nightstick-product-
support/warranties. Retain your receipt for proof of purchase.
Veuillez lire ces directives avant d'utiliser votre lampe à angle admissible
rechargeable Nightstick XPR-5572 à sécurité intrinsèque. Elles contiennent des
renseignements importants et des consignes d'utilisation.
LA LAMPE XPR-5572 EST APPROUVÉE POUR UTILISATION
Permissible Nightstick XPR-5572 Flashlight/Floodlight
TESTED FOR INTRINSIC SAFETY IN METHANE-AIR MIXTURES ONLY
WARNINGS: Do not charge in hazardous location. MSHA approved for use with Bayco
Li-ion Battery Pack 5572-BATT or Primary 5570-BATT Battery Pack containing 6 AA
Energizer Type EN91 or E91 batteries. Replace the Battery Pack in fresh air only. Do not
mix batteries from different manufacturers or different types. Battery Pack to be replaced by
a qualified technician only. The Model Nightstick 5572 must not be opened in areas where
permissibility is required. Substitution of components may impair Intrinsic Safety.
E 467756
CLASS I DIV 1 GRPS A-D T4
ID 4001184
CLASS II & III DIV 1 GRPS E-G
CLASS I ZONE 1 AEx ia IIC T4 Gb
CLASS II ZONE 20 IIIC
0359
Ex ia IIC T4 Gb
II 2 G Ex ia IIC T4 Gb
Ce produit est conforme aux normes IEC 60079-0, 6th edition, EN 60079-0:2012 +
A11:2013, UL 60079-0 6th ed, CAN/CSA C22.2 No. 60079-0: 2015, IEC 60079-11, 6th
edition EN 60079-11:2012, UL 60079-11 6th ed, CAN/CSA C22.2 No. 60079-11:2014,
UL 913 5th edtion, and CAN/CSA C22.2 No. 157-92.
AVERTISSEMENTS – SÉCURITÉ INTRINSÈQUE
y Avertissement : Utiliser uniquement le bloc-piles rechargeable au lithium-ion
Nightstick 5572-BATT approuvé ou les piles non rechargeables approuvées et
énumérées ci-dessous.
INS-XPR-5572GA/RA-16
Switch, and the light will remain in that brightness mode.
To turn the Floodlight off, press and release the Floodlight
Switch one more time.
Dual-Light Mode
Dual-Light mode allows the user to turn on both the
Flashlight and the Floodlight at the same time. Dual-Light
mode can be activated by simply pressing the Flashlight
Switch and then the Floodlight Switch or the Floodlight
Switch and then the Flashlight Switch (Image 18). If the
Angle Light already has the Flashlight or the Floodlight
on (regardless of what brightness mode that light is
in), pressing the switch for the light that is NOT on, will
activate Dual-Light mode. The user can leave Dual-Light
Mode d'emploi
XPR-5572
APPROVAL No. 20-A150005-0
Ex ia FLASHLIGHT FOR USE IN HAZARDOUS LOCATIONS
UL listed for use with Bayco Li-ion Battery Pack
5572-BATT or Primary 5570-BATT Battery Pack
containing 6 AA Energizer Type EN91 or E91 batteries.
Ex ia IIC T4 Gb
DEMKO 16ATEX1773
IECEx UL 16.0115
-20ºC ≤ Tamb ≤ +40ºC
3.7V/Cell
U
= 4.75V
m
07-23-2018

Publicidad

Tabla de contenido
loading

Tabla de contenido