4
AIMING
FIGURE 4
A "sight track" for point aiming is located on the top of
the luminaire above the door locking screw. Align the
front and rear sights so that they have equal space
showing on either side of the groove and the target
centered in the groove.
60° MAX
FIGURE 5
PE Units: For units with photo electric receptacle, fixture
cannot be aimed more than 60° degrees above horizontal.
5
WIRING
• Verify that supply voltage is correct by comparing it
to the nameplate.
• Units provided with cable or leads exiting the fixture
for connection with service leads.
• If cable or leads are removed and customer connects
service leads directly to the terminal board, see table
below for screw torque requirements.
Table 1. Terminal Board Torque Table UL Units:
Wire Range Copper
10-16 SOL,STR
8-6 SOL,STR
Front of sight
Target
Rear of sight
Aluminum
Torque (in lbs)
30
STR6, SOL, STR
45
6
MAINTENANCE / CLEANING
Risk of electric shock. Make certain power is off before
attempting any maintenance.
• To maintain high efficiency of the lens, occasional
cleaning of the outer lens surface may be needed,
with frequency dependent on local conditions.
• Use a mild soap or detergent, which is essentially
neutral pH (pH approximately 6 to 8), nonabrasive,
and which contains no chlorinated or aromatic
hydrocarbons.
• Wash thoroughly, using a soft cloth.
• Rinse with clean, cold water and wipe dry.
7
STORAGE
• Prior to installation, units should NOT be stored
outside in corrugated boxes (cardboard boxes) alone.
• Until installation, all units should be placed in a
covered dry storage area. The storage area should
not exceed -40°C (-40°F) to 50°C (122°F).
-
This can be preferably in a roofed area or with a
tarp that is secured in such a way to keep water
off of the corrugated boxes (cardboard boxes).
8
CONTROLS
External Dimming Control (If Applicable):
• Gray Lead = 0VDC (-)
• Violet Lead = Up To 10VDC (+)
• For dimming input to luminaire wattage/lumen
output see specific driver data sheets.
PE Dimming Control (If Applicable):
• No external connections for Dimming are required
when the GE Dimming PE Control or GE Dimming
PE Receptacle is used.
• All dimming control connections will be made
between the Dimming PE and Luminaire through the
included PE Receptacle.
• Refer to instructions included with GE Dimming PE
Control regarding appropriate settings for dimming
control.
WARNING