All dc and ac units have selectable alarm sounds as detailed below and
are selectable by means of a 5 way dil switch. A second sound is made
available upon the application of a third wire connected to terminal 3 as
shown in Figure 1 while still connected to terminal 2. Alternatively 1st
and 2nd stage sound signals can be generated by supply reversal
(FOR DC UNITS ONLY) see Figure 2. Independant second stage
sound is available on request (DC only).
Sound Signals, Output and Supply Current
First
Stage
Signal
1 Alternate 2-tone
2 Alternate 2-tone
3 Alternate fast 2-tone
4 Alternate fast 2-tone
5 Alternate 2-tone
6 Alternate 2-tone
7 Alternate v fast 2-tone 800-1000
8 Alternate v. fast 2-tone 2500-3200
9 Alternate 2-tone
10 Continuous note
11 Continuous note
12 Continuous note
13 Continuous note
14 Continuous note
15 Interrupted tone
16 Interrupted tone
Interrupted tone
17
18 Interrupted tone
19 Interrupted tone
20 Interrupted tone
Interrupted tone
21
22 Interrupted tone
23 Interrupted tone
24 Interrupted tone
25 Int, fast, rising volume 1400
26 Fast siren
27 Rising constant, fall
28 ISO 8201 Evacuation
29 Fast whoop
30 Slow whoop
31 Reverse sweep
32 Siren
The PFEER sound signals recommended by UKOOA are:-
General Alarm
Sound Signal 15
PAPA
Sound Signal 31
Toxic Gas
Sound Signal 11
Mounting:
The Y05 series alarm units are mounted to a wall or bulkhead of suitable material using the lugs projecting from the side of the case. The lugs
are bored 8mm clearance on 153mm centres. The recommended length of fixing screws is 25mm. To maintain the integrity of the weather seal,
the cable entry must be via a suitable sealed gland.
RS Components shall not be liable for any liability or loss of any nature (howsoever caused and whether or not due to RS Components' negligence) which may result from
the use of any information provided in RS technical literature.
4
RS Stock No.
230V Red Beacon
230V Amber Beacon
2nd sound
Freq.
rept.
stage
rate
signal
800-1000
0.5
3
2500-3100
0.5
4
800-1000
0.25
7
2500-3100
0.25
8
440-554
0.4/0.1
14
430-470
1.0
14
0.13
12
0.07
13
440-554
2.0
10
700
-
1
1000
-
31
1000
-
7
2300
-
2
440
-
9
1000
2.0
31
420
1.25
30
1000
0.5
1
2500
0.25
4
2500
0.5
2
700
6/12
10
1000
1.0
32
700
4.0
10
700
0.25
10
720
0.7/0.3
10
0.25
26
250-1200
0.085
11
1000
10/40/10 17
800-1000
as std
11
500-1000
0.15
32
500-1200
4.5
12
1200-500
1
11
500-1200
3.0
26
switch settings: ON=1 and OFF=0
Interrupted tone 1000 Hz
Reverse Sweep 1200-500 Hz
Continuous tone 1000 Hz
566-780
566-774
switches
sound output dB(A) and input current in mA
1 2 3 4 5
24Vdc
dB(A) mA
1 1 1 1 1
101
40
0 1 1 1 1
107
70
1 0 1 1 1
101
40
0 0 1 1 1
106
69
1 1 0 1 1
98
27
0 1 0 1 1
98
26
1 0 0 1 1
100
38
0 0 0 1 1
106
68
1 1 1 0 1
99
29
0 1 1 0 1
99
31
1 0 1 0 1
101
40
0 0 1 0 1
101
40
1 1 0 0 1
104
57
0 1 0 0 1
97
25
1 0 0 0 1
101
40
0 0 0 0 1
97
25
1 1 1 1 0
101
38
0 1 1 1 0
106
55
1 0 1 1 0
107
62
0 0 1 1 0
100
32
1 1 0 1 0
101
40
0 1 0 1 0
100
32
1 0 0 1 0
98
28
0 0 0 1 0
99
32
1 1 1 0 0
103
45
0 1 1 0 0
100
32
1 0 1 0 0
101
39
0 0 1 0 0
101
40
1 1 0 0 0
99
30
0 1 0 0 0
102
39
1 0 0 0 0
99
34
0 0 0 0 0
101
38
115Vac
230Vac
dB(A) mA
mA
special application
102
26
14
Fire alarms
106
34
17
Security alarms
101
26
14
Increased urgency
106
33
18
Security deterrent
98
22
12
AFNOR, France
98
22
12
101
26
14
105
33
19
98
23
13
Turn-out, Sweden
99
24
13
All-clear, Sweden
101
26
15
101
26
15
104
31
18
98
21
12
102
26
15
98
21
12
AS2220,
101
25
14
106
28
15
107
31
17
100
24
14
Pre-vital message Sweden
101
26
15
Local warning, Sweden
100
24
13
Industrial alarm, Germany
98
21
12
100
23
13
103
26
15
100
25
13
102
26
14
Industrial alarm, Germany
101
26
14
Int'l evacuation alarm
100
24
12
101
26
14
Evacuation,The Netherlands
100
24
13
Evacuation, Germany
101
24
14
AUSTRALIA