Functioning
● There will be a DRP-2 per plant that you wish to control.
● Each DRP-2 will be programmed with the range of monitor codes that belong to its plant. Page 3.
● The way to activate the DRP-2 will be with the "Key" button of the monitor. Only when receiving a call from panel.
● There are 2 installation variants:
1. The system has a panel that belongs to the elevator and another panel/s that are used to enter into the building. The
lift panel must have set Self-starting NO and the same code as all DRP-2's.
ALWAYS DIFFERENT FROM 0 AND DIFFERENT FROM THE PANEL/S OF ACCESS TO THE BUILDING. Page 6.
The visitor will call from the external panel and the user will press the "Key" button of the monitor, the system will
recognise that it is not an elevator panel and will only open the entrance door. When the visitor arrives to the elevator,
will call the house again from the lift panel, the user will press again the button "Key" of the monitor. The system will
recognise that it is an elevator panel and will send it to pick up the visitor. When it reaches the ground floor, it will
open the doors to allow its entry, then it will go to the floor from which the opening was made. It will open the door
and allow the visitor to get off on the right floor.
All automatically and without need of install buttons outside or inside the elevator.
2. The system only has one panel/s installed to enter the building and also operate the elevator. The panel/s must have
the Self-starting NO and the same code as all the DRP-2's. ALWAYS DIFFERENT FROM 0. Page 6.
The visitor will call from the external panel and the user will press the "Key" button on the monitor. The system will
open the entrance door, allowing the visitor to enter in the building and send the elevator to pick it up. When it
reaches the ground floor, it will open the doors to allow its entry, then it will go to the floor from which the opening
was made. It will open the door and allow the visitor to get off on the right floor.
All automatically and without the need of install buttons outside or inside the lift.
DRP-2's
DRP-2
DRP-2
DRP-2
COD. 1
Lift panel
(SELF-STARTING: NO)
COD. 1
COD. 1
COD. 2
COD. 3
COD. 4
DRP-2's
DRP-2
DRP-2
DRP-2
COD. 1
COD. 1
COD. 1
COD. 1
Panel/s at building
entrance
Panel/s at building
entrance.
SELF-STARTING: NO
Bringing people together