Check stopping of the machine!
Check whether the machine stops when the
emergency button is pressed.
Danger
Procedure in the event of a fault
In the event of a mechanical overload or the
exertion of external force, damage and
operational faults of the Emergency-Stop button
may result. Carry out operational test as
described in point 7.
7
Regular technical inspections
The inspection interval is to be defined by the designer with the aid of
a risk analysis. However, it is recommended that the responsible
safety officer trigger the Emergency-Stop button at least once a year
and check correct operation.
- trouble-free operation
- no manipulations detected
- safe attachment of the components
- tightness of the cable bushings
- no loose cable connections
8
Further operating instructions
The Emergency-Stop buttons for hygienic environments (NHT02D)
may only be cleaned with the following cleaning agents:
Note:
- good resistance against acids, alkalis and alcohols
- no/limited resistance against hydrocarbons
(petrol, oil etc.)!
- high ozone- and UV-resistance
9
Disposal
Dispose of packaging and used parts in accordance with the
regulations of the country in which the device is installed.
10 Order details
Contact elements
NC / NC
NC / NC + failure protection
NC / NC + failure protection / illumination
NC / NC / NO
NO / NC / NC + failure protection
NO / NC / NC + failure protection / illumination
Accessories
Emergency-Stop enclosure
Installation wrench
Push-button
Twist to release
Twist to release, suitable for hygienic
environments
as per DIN EN 1672-2 and GS-FW
With blocking protection, twist to release
With blocking protection, twist to release,
illuminated
With blocking protection, key-release, illuminated NHT04S
With protective collar, twist to release
EC Declaration of Conformity
We declare that the safety components described in the following
comply with the following directives:
2006/42/CE
Applicable harmonised standards:
EN 60947-5-5:1997 + A1:2005, EN ISO13850:2008
Designation of the safety component:
Emergency-Stop push-button NHT0.. / contact elements KE2....
Description of the safety component:
Emergency-Stop control unit
Leutkirch, 08.03.2010
Michael Hetzer,
General Manager
Order
designation
KE20
KE20SF
KE20FSB
KE21
KE21SF
KE21SFB
NHG01
MS01
NHT01D
NHT02D
NHT03D
NHT04D
NHT05D
elobau
GmbH & Co. KG
Zeppelinstraße 44
88299 Leutkirch
Germany
Dieter Reinsch,
Tel.: +49 7561 970-0
Documentation
Fax: +49 7561 970-100
e-mail: info@elobau.de