There are several methods of grounding the Pro-
caster. We recommend using a ground rod as the
most straightforward method.
Ground rod
The simplest and most popular method is to use a
5/8in x 8ft ground rod (steel core surrounded by
copper) driven into the ground full length. Several
ground rods spaced 6ft apart and joined together
can further reduce the resistance to ground. Keep-
ing the ground moist by locating rods near an air
conditioner drip point or run-off from a roof down-
spout can also reduce overall ground resistance.
The following parts may be obtained from your
local hardware store:
© 2020 Chezradio Inc.
PROCASTER
AM Transmitter
Hay varios métodos para atierrar el Procaster.
Recomendamos utilizar una varilla de tierra como
el método más sencillo.
Barra de tierra
El método más simple y popular es utilizar una
varilla de tierra de 5/8" x 8 ft (núcleo de acero
rodeado de cobre) accionada en toda la longitud
del suelo. Varias varillas de tierra separadas a 6
pies y unidas pueden reducir aún más la resisten-
cia al suelo. Mantener el suelo húmedo localizan-
do varillas cerca de un punto de goteo del aire
acondicionado o escorrente desde un techo hacia
abajo también puede reducir la resistencia general
al suelo. Las siguientes piezas se pueden obtener
de su ferretería local: