Connecting Auto Iris Lens Connector
Prepare the following Auto Iris Lens Connector supplied
with the camera.
Rib
Pin3
Pin1
Connect the cable of the control cable, whose covering is
stripped, to the Auto Iris Lens Connector as shown below.
Pin Number DC Control Type Video Control Type
1
Damp(-)
2
Damp(+)
3
Drive(+)
4
Drive(-)
6
User Guide
Pin4
Pin2
Power Source (+9V)
Not used
Video Signal
GND
Mounting the Lens
Loosen a screw fixing the Flange Back Adjustment Ring by
turning it counterclockwise and turn the Adjustment Ring to
the "C" direction (counterclockwise) until it stops. Failure to
do so may result in a damage caused by the bump of the lens
against the image sensor part in the camera when mounting
the lens.
C Direction
Auto Iris Control Cable
7
User Guide
E