Maintenance
Cleaning the Water Filter
• Unscrew and remove the cover (drawing 6).
• Clean the filter element thus exposed.
• Refit the cover.
Checking and Adjusting the Pressure Switch (drawing 7)
Switch on pressure: Open a tap a quarter of a turn only. As the water
runs out slowly the pressure will reduce. Now watch the manometer
for the pressure at which the pump is switched on.
Increase switch-on pressure : Turn nut 2 to the right.
Decrease switch-on pressure : Turn nut 2 to the left.
Switch-off pressure: Leave the tap open quarter of a turn, so that the
water pressure in the tank increases slowly. Now watch the manom-
eter to read the pressure at which the pump is switched off.
Increase switch-off pressure: Turn nut 1 to the right.
Decrease switch-off pressure: Turn nut 1 to the left.
N.B. Nut 1 adjusts the difference between switch-on and switch-off
pressure. After resetting the switch-on pressure, the switch-off pres-
sure must also be adjusted again.
6

Technical data

Type
Electric motor, type
Voltage
Current at 0.7 Bar (10 psi)
Pump, type
Capacity at 2 Bar (30 psi)
Max. pressure
Maximum riser height
Filter, type
Mesh size
Pressure switch
Settings,
Switch-on pressure
Switch-off pressure
Range,
Min. switch-on pressure
Max. switch-off pressure
Manometer
Meter range
Pressure tank
Capacity
Pre-pressure, air cushion
Connections,
Hose
Water temperature
Weight
Pressurized-water system HYDRF12, HYDRF24, HYDRF1219, HYDRF2419
HYDRF12
:
:
:
12 V DC
:
3.9 Amp
:
:
12.5 litres/min (2.7 Imp.Gallon)
:
2.5 Bar (36 psi)
:
:
:
:
:
:
:
:
:
8 litres (1.75 Imp.Gallon)
:
1.2 Bar (17 psi)
:
12.7 mm (1/2")
:
:
8.2 kg (18 lb)
Checking and pressurizing Pre-pressure and Air Cushion
Remove the protective cap, turn to the left and check pressure with
a tyre air pressure meter.
Reduce pressure: Push the Schräder valve pin in; air will now escape.
Increase pressure: Connect a car tyre pump to the valve and bring
the air cushion to the required pressure.
Replacing the Membrane
Under normal circumstances the membrane should never need
replacement. However if it does leak, replace as follows:
• Ensure that the whole system is de-pressurized.
• Remove the hose between pump and T-piece, remove the 6 bolts
holding the flange to the top of the tank and remove flange com-
plete with T-piece.
• Remove the old membrane, refit a new one and reassemble in re-
verse order to the above.
HYDRF24
HYDRF1219
Permanent magnet DC motor
24 V DC
12 V DC
2.0 Amp
6.0 Amp
Self-priming 4 valve diaphragm pump
3 m (10 ft)
In-line
40 Mesh
1.4 Bar (20 psi)
2.5 Bar (36 psi)
0.8 Bar (12 psi)
4.8 Bar (70 psi)
0 to 6 Bar (0 - 87 psi)
0 to 50 degrees C. (32 to 122 degrees F.)
ENGLISH
HYDRF2419
24 V DC
2.5 Amp
17.0 litres/min (3.7 Imp.Gallon)
2.8 Bar (40 psi)
19 litres (4.2 Imp.Gallon)
1.2 Bar (17 psi)
19 mm (3/4")
9.5 kg (20.9 lb)
050404.03
5

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Hydrf24Hydrf1219Hydrf2419