If the unit is off, pushing Timer will start the Auto-On start feature, and pushing it again within 5
seconds will switch it to the Auto-Off stop feature.
Press or hold the UP or DOWN button to set the Auto time in 0.5 hour increments, up to 10
hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining
until starting or stopping.
After 5 seconds, the system will revert back to showing the humidity level on the display.
When the Auto start & Auto stop times are both set within the same program sequence, TIMER
ON and OFF indicator lights illuminate identifying both ON and OFF times are now programmed.
Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto
Start/Stop timer program.
If the P2 code occurs, the Auto Start/Stop program will be cancelled.
f.
and
(Humidity Set Control Buttons): The humidity level can be set within a range of 35% RH
(Relative Humidity) to 85% RH in 5% increments. The lower the set % is, the drier the air will be.
g.
Indicator Lights
Filter – Filter needs to be cleaned
Comfort - Comfort dehumidifying light
Cont. - Continuous dehumidifying light
On (Timer on light) – Auto On/Start set.
h.
LED Display: Displays the relative humidity level for the room (±5%) within a range of 30%-90%.
While setting, displays the set level for humidity between 35%-85%, or the auto start/stop time
(0~24), along with error or protection codes.
Error Codes
AS: Humidity Sensor error
ES: Temperature sensor error
EC: Refrigerant leakage (on models with this feature)
NOTE: If the display shows one of the above codes turn off and unplug the unit, and check for any
obstructions or empty the water tray, then restart. If code is still present, turn off again and unplug,
and contact customer service or service technician for assistance.

SMART FUNCTIONS

Auto Shut Off: When the water "Full" indicator light turns on or the humidity setting is reached, the
unit will be shut off automatically.
Delayed Start: When the unit has stopped or power is interrupted, it will not restart for 3 minutes to
protect the cooling system. The dehumidifier will automatically start after 3 minutes have passed.
Auto Defrost: When frost builds up on the evaporator coils, the compressor will cycle off and the fan
will continue to run until the frost melts.
Auto-Restart: If the power is lost or cut, the unit will restart with the previous function setting
automatically when the power resumes.
Turbo - High fan light
Full (Bucket full light) – Empty water bucket
Auto Defrost - Auto defrost on
Off (Timer off light) – Auto Off/Stop set
Protection Code
P2: Water bucket full or incorrectly
installed
9