Start Up - Truper TPN-883 Instructivo

Remachadora neumática
Ocultar thumbs Ver también para TPN-883:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Start Up

Air Inlet Connection
• Connect the air hose to the tool with an adapter (not
included). Screw the adapter to the tool. Air inlet connection.
• If using various pneumatic tools and only one compressor, a
fast coupling (not included) is recommended, together with the
adapter, to quickly connect and disconnect the tools and
interchange them easily.
Turning ON
• Turn ON the air compressor until is full.
• Regulate the compressor air outlet pressure, from 80 PSI,
up to 100 PSI.
WARNING
The tool operates in the pressure range
mentioned above. If operating in a higher range, the service
life of the machine will be shorter.
• Let some air running through the hose and the coupling to
verify both are clean before connecting into the tool.
Operation
• Insert the rivet stem in the river nozzle.
• To hold the rivet in any position, see the section
"Vacuum System".
• Find the orifice to put the rivet into and insert the rivet
head in it.
• Hold firmly the riveter and press the trigger.
• Release the trigger and remove the riveter.
Vacuum System Adjustment
• To activate the vacuum system, turn the adjusting knob
counterclockwise until getting the desired rivet fastening.
NOTE
When activating the vacuum system, the air
pressure lowers, therefore the working pressure needs
adjusting. See the "Turning ON" section.
WARNING
When not operating in the pressure
range established, the riveter cannot separate the stem
from the rivet.
• To deactivate the vacuum system, turn the adjusting
knob clockwise.
Air Inlet
Connection
Adapter
Air
Hose
Trigger
ENGLISH
7

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Tpn-8841824018241

Tabla de contenido