INSTALLATION: see page 5 - diagrams 1 to 4.
Notes:
1) To install the angle stops. They adjust the flow rate, filter the water and have check valves to prevent cross
connection.
MAINTENANCE: see instructions below and diagrams at page 6.
PROBLEM
Water does not flow or
flow volume too low
Water flows continuously
(leak)
Water flow time too short
Water flow time too long
Flow volume too high
Leak under the button
Temperature cannot be
adjusted
THIS PACKAGE CONTAINS: 1 mixer,
SPARE PARTS AND COMPONENTS: Available at Docol Authorized Distributor in your country/ Export Departament +
55 47 3451-1114 or export@docol.com.br.
CARE AND CLEANING: only use soft cloth, water and soft soap at twice a week. Occasionally can be applyed
automobiles wax. Do not use abrasive products.
COMPOSITION OF PRODUCT: Copper alloys, elastomers, engineering plastics and stainless steel.
INSTRUCTION STICKER: stick it at the wall close the mixer.
WARRANTY: see page 8.
For a better perfomance of the hydraulic system, we recommend following a project made by a specialized professional
as well as all relevant standards and the installation standard.
PROBABLE CAUSE
Water supply interrupted
Angle stop valve not opened
Angle stop filter clogged
Aerator clogged
Piston damaged (diagram 9-part C)
Spindle damaged (diagram 9-part B)
Seat damaged (diagram 9-part D)
Piston damaged (diagram 9-part C)
Cylinder damaged (diagram 9-part A)
Piston Damaged/clogged (diagram 9-part C) To replace
Angle stop not installed
Angle stop totally opened
Retainer damaged (diagram 9-part E)
Spindle damaged (diagram 9-part B)
Angle stop filter clogged
Mixing shaft faultly
2 angle stops, 2 flexible hoses, 1 aerator tool and 1 instruction sticker
ENGLISH
SOLUTION
To check/open the water supply
To open it
To clean or to replace (diagram 10)
To clean or to replace (diagram 11)
To replace
To replace
To replace
To replace
To replace
To install and to adjust (diagrams 3 - 5)
To adjust the flow rate (diagram 5)
To replace
To replace
To open or to clean
To replace
(diagram 5)
(diagrams 6 - 9)
(diagrams 6 - 9)
(diagrams 6 - 9)
(diagrams 6 - 9)
(diagrams 6 - 9)
(diagrams 6 - 9)
(diagrams 6 - 9)
(diagrams 6 - 9)
(diagrams 6 - 9)
(diagrams 6 and 12)
.
4