L7224A,C; L7248A,C,L OIL ELECTRONIC AQUASTAT
R7184
5
ENVIRACOM™
TERMINAL
TO REMOTE
ALARM
2
CIRCUIT
LEGEND
SCREW TERMINAL
SOLDERLESS WIRE CONNECTION
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
OPTIONAL FEATURE ON SELECT MODELS.
2
3
REFER TO DEVICE LABEL FOR WIRE COLOR CODE.
Fig. 10. L7224A,C single zone system with circulator and indirect water tank with EnviraCOM™ thermostat.
68-0281EFS—05
3
2
TH9421C
T
LIMIT
T
L1
3
L2
2
1
3
BURNER
BURNER
MOTOR
MOTOR
3
IGNITOR
IGNITOR
3
VALVE
VALVE
CAD
CAD
CELL
CELL
JUNCTION
BOX
1/4 IN. (6 MM) QUICK CONNECT TERMINAL
®
CONTROLLERS
50022037-002
OUTDOOR
RESET MODULE
1
1 2 3 OT OT
C7089U1006
6
OUTDOOR
SENSOR
L1
3
2
1
(HOT) L2
1
L7224
SENSOR
7
ZR
L1
LINE
VOLTAGE
L2
CIRCULATOR
4
C2
B2
C1
B1
ZC
4
VALVE IS OPTIONAL ON SPECIFIED MODELS.
5
ENVIRACOM™ TERMINAL 3 IS ALSO THE FIRST THERMOSTAT TERMINAL.
6
OPTIONAL OUTDOOR RESET MODULE AND OUTDOOR SENSOR.
DUU MUST BE SET TO "ON" ON THE AQUASTAT.
7
12
LINE VOLTAGE
INDIRECT
TANK AQUASTAT
INDIRECT
TANK
CIRCULATOR
L2
T
T 3
2
1
M32025