Ocultar thumbs Ver también para MXS 5.0:
Tabla de contenido

Publicidad

CHARGING PROGRAMS AND OPTIONS
Press the MODE-button to select between the charging programs and to add charging options. The LEDs will indicate which pro-
grams and options that are selected. The selected program will be memorised and restarted next time the charger is connected.
The table explains the different Charging Programs:
Program
Battery Size (Ah)
1.2–14Ah
14–160Ah

Charging Options

Option
Explanation
AGM option
AGM
Use for charging most AGM batteries like Optima and Odyssey.
Recond option
Use to return energy to the empty WET and Ca/Ca batteries. Recond your battery
RECOND
once per year and after deep discharge to maximise lifetime and capacity. The Recond
program adds STEP 6 to the normal battery program.
10 • EN
50013552C MXS 5.0 NA, Manual, Print file 002.indd 8
Explanation
Small battery program
14.4V/0.8A. Use for smaller batteries.
Normal battery program
14.4V/4.3A. Use for WET batteries, Ca/Ca, MF, GEL batteries and many AGM
batteries.
Temp range
-4ºF–122ºF
(-20°C–+50°C)
2016-11-21 15:01:26

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1090

Tabla de contenido