Multiline AC

Pump filling

• The AC pump can be filled either through the filler cap in the lid (1), or via the
grease nipple fill point (22). Initial filling should be through the grease nipple to
prevent against any air pockets in the pump chamber or reservoir.
• Systems Lubricants & Filling Methods All Groeneveld Systems' multiline pump
options are fitted as standard with both bulk top fill (suitable for oil and fluid
grease up to NGLI '000') and bottom fill adaptors for filling of grease NGLI to Grade
2-this avoids the possibility of air entrapment. (for recommend lubricants see
Groeneveld installation manual for AC15XX & AC25XX page 6).
• If the reservoir must be filled through the reservoir cap molding (5), be certain
the cap (1) is secured to the reservoir cap molding (5) when finished. Take care to
prevent air pockets in the reservoir.
Programming procedure of the AC pumps
The programmable AC15/AC25 has the following settings available:
6
F219157R03
Setting
Run time
0
1
3 minutes
2
3 minutes
3
3 minutes
4
3 minutes
5
3 minutes
6
3 minutes
Delay time
Total cycle time
Continuous
6 minutes
9 minutes
9 minutes
12 minutes
12 minutes
15 minutes
27 minutes
30 minutes
42 minutes
45 minutes
57 minutes
60 minutes