INSTRUCTIONS MANUAL
PORT
USB
TIME
No save
MODE
Start
USB
0
LOG MENU
CORRECT T
CORRECT. T
(0) 37ºC
ALM SOBRE T
ALARM SOBRE T
0.0 ºC
ALM BAJO T
ALARM BAJO T
0.0 ºC
AJUST T.S.
ALARM SOBRE T
80ºC
COMP. ON
CORRECT. T
inf
COMP. OFF
ALARM SOBRE T
- - - -
RET. VENT.
ALARM SOBRE T
- - - -
Tª INI COMP
ALARM BAJO T
30 ºC
TEMPERATURE SETTINGS MENU
J
.P. SELECTA s.a.u.
CODE 80381
REV A
Log menu
The equipment can store readings from time to time and store them
lately in a USB memory pen.
«PORT»
• USB:
«INTERVAL»
«MODE»
• Start:
• Set point:
«USB»
Set the temperature and the temperature alarms
It is recommended to verify calibration of temperature with some regu-
larity (for example, annually), by using for instance a thermometer or
a temperature pattern.
If it is necessary to correct the reading, as a result of calibration, one
must enter a correction. To do this, press on the temperature menu
A box indicating the current correction value appears.
Adjust with keys
temperature pattern. Applied correction will appear in brackets.
Temperature alarms
By pressing successively on the temperature correction box, one may
enter an over-temperature (Alm sobre T) and low-temperature (Alm
bajo T) limit. Both alarms activate a message on screen.
T.S. settings
This parameter sets the maximum value of the safety thermostat (do
not touch)
Comp. ON
Adjust the operating time of the compressor.
Comp. OFF
Adjust the compressor shutdown time.
RET.VET
Adjust the delay of entry into operation of the indoor fan.
Tª INI COMP
Adjust the temperature from which the compressor stops working.

Temperature units

Press on the Units menu. Press successively to change between Celsius
or Farenheit degrees.

Set language

Press on the Language menu. Press successively on the box to select
among Spanish, French or English.
Adjust by pressing on the increase and decrease icons.
Ctra. NII Km 585.1 Abrera 08630 (Barcelona) España
e-mail:selecta@jpselecta.es - web site: www.jpselecta.es
FEBRUARY 2020
Set the readings storing mode:
Store the readings in a USB memory pen drive.
Select the log time interval of a data, with the keys
Select the data to be stored:
Save all temperature readings.
Save temperature readings, since the set point tem-
perature has been reached.
Update the firmware from a file that is in a USB.
until the you get the indicated value on the
Tel 34 937 700 877 Fax 34 937 702 362