• Never touch the bulb with your bare hands, as oil from your skin can
cause premature failure. Always handle the bulb with gloves or a
soft cloth.
• Disassembly of your fixture will void the warranty.
• For supply connections, use wire rated for at least 75° C.
• In the event of glass breakage, the entire lens cover must be replaced.
Contact Customer Service for ordering assistance.
Installing the bulb
Step 1: Remove screws that hold glass lens frame assembly in place.
Remove glass lens frame assembly.
Step 2: Using a clean cloth or gloves, remove bulb from package and
protective wrap. NOTE: Never touch bulb with bare hands as
oil from your skin can cause premature failure.
Step 3: To install bulb, position bulb into spring loaded socket and push
bulb toward socket until it depresses. Position other end of bulb
into stationary socket (opposite socket). Be sure each end of
bulb is securely positioned against socket.
Step 4: Replace glass lens frame assembly making sure that the
weatherproof gasket is properly seated. Replace and tighten
the screws that secure the lens frame assembly.
Assembling your fixture
Step 1: Refer to the back of the fixture for mounting arrow showing
correct upright installation position.
Step 2: Loosen the swivel bolt (G) located on
the back of the fixture.
Step 2: Thread the junction box cover-
plate (H) onto the mounting
arm (F) and secure with the
locknut provided (B), using
pliers to tighten. NOTE: The locknut
should be on the outside of the junction coverplate.
Wiring your fixture
NOTE:This fixture should be mounted to a grounded junction box
(not included).
Step 1: Turn off the power at the main fuse/breaker box.
Step 2: Connect the white house supply wire to the white fixture wire
using a wire nut. NOTE: Wire nuts not supplied. Connect the
black house supply wire to the black fixture wire using a wire nut.
Step 3: Attach ground wire coming from your house to the ground wire
from the fixture using wire nut. If no ground wire exists from the
house supply, connect the ground wire from the fixture to the
junction box.