Extension Cords

If an extension cord must be used, be
sure it is:
a 3-wire extension cord that has a
3-blade grounding plug, and a 3-slot
receptacle that will accept the plug on
the product
in good condition
no longer than 50 feet
14 gauge (AWG) or larger. (Wire size
increases as gauge number decreas-
es. 12 AWG and 10 AWG may also be
used. DO NOT USE 16 OR 18 AWG.)
Risk of Property
Damage. The use
of an undersized extension cord
will cause voltage to drop resulting
in power loss to the motor and
overheating. Instead of using
an extension cord, increase the
working reach of the air hose by
attaching another length of hose to
its end. Attach additional lengths of
hose as needed.

Voltage and Circuit Protection

Refer to the specification chart for the
voltage and minimum branch circuit
requirements.
Risk of Overheating.
Certain air
compressors can be operated on a 15
amp circuit if the following conditions
are met.
1.
Voltage supply to circuit must
comply with the National
Electrical Code.
2.
Circuit is not used to supply any
other electrical needs.
3.
Extension cords comply with
specifications.
4.
Circuit is equipped with a 15 amp
circuit breaker or 15 amp time
delay fuse. NOTE: If compressor
is connected to a circuit protected
by fuses, use only time delay
fuses. Time delay fuses should be
marked "D" in Canada and "T" in
the US.
If any of the above conditions cannot
be met, or if operation of the compres-
sor repeatedly causes interruption
of the power, it may be necessary to
operate it from a 20 amp circuit. It is
not necessary to change the cord set.
11 - ENG