2. INSTALLATION OF THE HOOD ON THE LOWER PART OF THE WALL UNIT ON THE
DIVIDING PANEL.
Follow the steps below:
1 -Check the measurements indicated in fig.1-2 and the minimum distance from the hob,
before installing the hood on the dividing panel.
3- Make sure the thickness of the wall unit is within the parameters indicated in figure
4 - step 2.
4- Build the hood in the wall unit and make sure the 2 side springs F are connected
correctly. Fasten the hood to the wall unit using the screwdriver and the relative screws
M and tighten until the device is firmly against the wall unit (figure 4 - step 2).
5- Fasten the hood to the upper wall unit as indicated in figure 5 - step 6.
- Once you have fastened the hood to the wall unit, adjust the spacer L, with screws P, to
make the device line up with the rear wall unit (figure 4 - step 5).
IMPORTANT - The range hood must be secured to wall studs or use drywall
anchors capable of supporting 75 lbs.
- 12 -