XC510 AIR CONDITIONER/DEHUMIDIFIER
TROUBLESHOOTING
If the air conditioner is not working properly, it is usually due to a minor problem
that the user can handle. Before calling customer service, please check the following
points.
Problem
The air conditioner
/ dehumidifier is not
working.
The air conditioner cuts
out.
The "RUN" LED indicator
light flashes and the
alarm sounds.
The LED display shows
the unit is set but it is
not running.
"E1" Displayed on LED
Panel
"E2" Displayed on LED
Panel
"E5" Displayed on LED
Panel
"E7" Displayed on LED
Panel
Probable Causes
Plug not properly inserted
into power socket.
A fuse has blown.
Water tank is full / alarm
light is on
Waste-air hose is too long
or kinked.
Unit is too close to wall or
another object
The appliance is covered.
The "timer off" function
has been activated.
Room temperature is not
between 61° and 90°F /
16° and 32° C.
The condensation tank is
full and the unit cannot
drain. This safety feature
turns off the conditioner to
protect it and prevent the
tank from overflowing
The "timer on" feature is
activated
Evaporator sensor fault
Room temperature sensor
fault
Overheating protection
fault
Water tank is full
12
Solutions
Plug the appliance in
properly.
Check fuses (minimum 10
A).
Drain off condensation.
Waste-air hose may only be
extended using max. 5', 4"
diameter PVC pipe of flex to
a total waste air length of
10' 03 3 m.
Unit should be at least 1
1⁄2' away from walls and
objects.
Unit will overheat if the
waste air cannot fully vent.
Push the power button to
turn unit on.
Switch the unit back on
when room temperature is
between 61°-90°F/ 16° and
32° C.
Drain unit from the run off
at the back of the unit.
This is normal.
Push the Power button
to turn the unit on and
deactivate the "timer on"
feature.
Contact authorised
customer service
Contact authorised
customer service
Contact authorised
customer service
Drain the water tank. The
appliance will switch on
when the water tank has
been emptied
INSTRUCTIONS