- GB -
− Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use.
− Ensure that the power connection cable cross section is not smaller than that of the rubber sheath with the
identification H05RN-F. Extension cables must meet DIN VDE 0620.
− Protect the plug connections from moisture.
− Only plug the unit into a correctly fitted socket.
Safe operation
− Never operate the unit if either the electrical cables or the housing are defective!
− Do not carry or pull the unit by its electrical cable.
− Route all cables such that damage is excluded and nobody can trip over them.
− Never open the unit housing or its attendant components, unless this is explicitly required in the operating
instructions.
− Only use original spare parts and accessories for the unit.
− Never carry out technical modifications to the unit.
− Only have repairs carried out by customer service points authorised by OASE.
− Keep the socket and power plug dry.
− Only operate the unit if no persons are in the water!
Installation
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
The unit can be set up either submerged (A) or dry (B).
General preparatory work: Bolt on the suction unit (3) and fit the pressure socket (2). Connect the desired hose for the
water feature to the pressure socket. Adapt stepped hose connectors to the water supply and return in accordance with
the hose diameter (C). Remove the pump foot, if necessary. For this purpose, press the pump foot to the rear, as
illustrated (D)
Submerged installation (A)
Operation with the pre-filter fitted. Push the pre-filter over the suction unit and fasten the filter using the bayonet clo-
sure. Place the unit in the water at the desired position. Ensure that the unit is fully submerged. Maximum installation
depth:4 metres.
Dry installation (B)
Bolt the suction unit on and turn the priming opening to an optimum position for priming and connecting the suction
hose. Connect the suction hose to the suction unit. Always position the unit below the water line to prevent dry running
and the intake of air when switching on and operating the unit. Risk of damage!
Never connect the unit to a water line.
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
Start-up
Attention! The pump must never run dry.
Possible consequence: The pump will be destroyed.
Protective measure: Check the water level at regular intervals. Always place the unit below water level.
This is how to connect the power supply:
Switching on: Connect power plug to the socket. The unit switches on immediately when the power connection is
established.
Switching off: Disconnect the power plug.
The pump power can only be controlled by an OASE current management unit.
Attention! The installed temperature monitor automatically turns the pump off, if it is overloaded. The pump
automatically switches on again once the motor has cooled down. Risk of accident!
8