INSTRUCTION SHEET
IGP Series Retrofit Kits
IGP-A-RFK and IGPHR-A-RFK grinder pump kits are direct, simplex replacements for existing positive
displacement systems.
These kits offer:
Fast, simple, easy installation
Epoxy-coated steel cover
Water-tight junction box for ease of installation and servicing
1-1/4" cast iron anti-siphon/check valve
1-1/4" NPT (SST) piping
Adjustable alarm float switch preset at factory
2 HP, 3450 rpm, high starting torque, automatic grinder pump with mechanical float switch
Tight cutting clearances for superior cutting action, grinding 414,000 cuts per minute
Quick disconnect plug in either square or round format
Rigid construction for ease of handling
Telescoping discharge (Models 515801, 515835)
Please examine your pump carefully to ensure that no damage occurred during shipment. If damage
has occurred, please contact the place of purchase. They will assist you in replacement or repair, if
required.
This product is covered by a Limited Warranty for a period of 24 months from the date of original pur-
chase by the consumer. For complete warranty information, refer to www.franklinengineered.com; or,
call Technical Support for a printed copy.
Specifications
Model
Phase
IGP-A-RFK
IGPHR-A-RFK
BEFORE GETTING STARTED
This equipment should be installed and serviced by technically
qualified personnel who are familiar with the correct selection
and use of appropriate tools, equipment, and procedures. Failure
to comply with national and local electrical and plumbing codes
and within FPS recommendations may result in electrical shock or
fire hazard, unsatisfactory performance, or equipment failure.
Know the product's application, limitations, and potential haz-
ards. Read and follow instructions carefully to avoid injury and
property damage. Do not disassemble or repair unit unless
described in this manual.
Refer to product data plate(s) for additional precautions, operat-
ing instructions and specifications.
Failure to follow installation or operation procedures and all
applicable codes may result in the following hazards:
Volts
Hz
1
208-230
60
1
208-230
60
Amps
Breaker Size
Watts
13.9
20
3200
16
20
3600
Risk of death, personal injury, or
property damage due to explosion, fire,
or electric shock.
Do not use to pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc.
Do not use in explosive atmospheres or hazardous locations
as classified by the NEC, ANSI/NFPA70.
Do not handle a pump or pump motor with wet hands or
when standing on a wet or damp surface, or in water.
When a pump is in its application, do not touch the motor,
pipes, or water until the unit is electrically disconnected.
If the power disconnect is out of sight, lock it in the open
position and tag it to prevent unexpected application of
power.
If the disconnect panel is not accessible, or under flooded
conditions, contact the electric company to stop service.
English
EN
HP
Shut Off
2
130 ft (39.6 m)
2
200 ft (61 m)

Publicidad

Tabla de contenido
loading

Resumen de contenidos para FPS IGP Serie

  • Página 1 • Do not use to pump flammable or explosive fluids such as and within FPS recommendations may result in electrical shock or gasoline, fuel oil, kerosene, etc. fire hazard, unsatisfactory performance, or equipment failure.
  • Página 2: First Steps

    INSTALLATION First Steps High voltages capable of causing severe Risk of bodily injury, electric shock, injury or death by electrical shock are or property damage. present in this unit. • This equipment must not be used by children or persons with •...
  • Página 3: Preparation For Assembly

    INSTALLATION Preparation for assembly Preparation for assembly Remove the packaging from the kit, retaining the assembly pack and instructions. 2. Thoroughly read the pump owner's manual to familiarize yourself with its operation. 3. Models with telescoping discharge (515801, 515835): Once the old assembly has been removed, measure the distance from the bottom of discharge to the bottom of the cover plate (Dimension A) then adjust the discharge on the new retrofit assembly to the same height.
  • Página 4: Replacement Parts And Dimensions

    REPLACEMENT PARTS AND DIMENSIONS REPLACEMENT PARTS AND DIMENSIONS PUMP FLOAT ALARM FLOAT CORDSET (REF) CORDSET (REF) PUMP CORDSET 16.75” (POWER) PUMP CORDSET (POWER) 6.50–7.00” PIPE COLLAR 8.00–8.50” TETHER A-N448 Item Part No Description Quantity Item Dimension 515861 IGP-A231-20 Pump For Telescoping Discharge models, see Step 515701 IGPHR-A231-30 Pump 3 in Preparation for assembly...
  • Página 5: Hoja De Instrucciones

    FPS puede provocar • No usar para bombear líquidos inflamables o explosivos como gaso- peligros de descarga eléctrica o incendio, desempeños insatisfac- lina, fueloil, kerosene, etc.
  • Página 6: Instalación

    INSTALACIÓN Primeros pasos Riesgo de lesiones graves o muerte por Riesgo de lesiones corporales, descarga eléctrica. descargas eléctricas o daños al equipo • Para reducir el riesgo de descarga eléctrica, desconecte la energía antes de trabajar en el sistema o cerca de él. Es posible •...
  • Página 7: Preparación Para El Montaje

    INSTALACIÓN Preparación para el montaje Preparación para el montaje Retire el embalaje del kit y conserve el paquete de montaje y las instrucciones. 2. Lea detenidamente el manual del propietario de la bomba para familiarizarse con su funcionamiento. 3. Modelos con descarga telescópica (515801, 515835): Una vez que se haya quitado el conjunto ante- rior, mida la distancia desde la parte inferior de la descarga hasta la parte inferior de la cubierta protec- tora (Dimensión A), luego ajuste la descarga en el nuevo conjunto de reacondicionamiento a la misma altura.
  • Página 8: Piezas De Repuesto Y Dimensiones

    PIEZAS DE REPUESTO Y DIMENSIONES PIEZAS DE REPUESTO Y DIMENSIONES Cableado de flotador Cableado de flotador de la bomba de alarma Cableado de 16.75” la bomba Cableado de la bomba 6.50–7.00” Cuello de tubo 8.00–8.50” Correa A-N448 N.° de Cantida Artículo Descripción Artículo...
  • Página 9: Kits De Rénovation De La Série Igp

    • N’utilisez pas l’appareil dans des atmosphères explosives ou des recommandations de FPS peut entraîner des risques de décharge zo-nes considérées comme dangereuses (classifiées dans les électrique ou d’incendie, des performances insatisfais-antes ou condi-tions définies par le NEC et ANSI/NFPA70.
  • Página 10: Premières Étapes

    INSTALLATION Premières étapes Risque de blessures graves ou de décès Risk of bodily injury, electric shock, par choc électrique. or property damage. • Pour réduire le risque de choc électrique, débranchez l’alimenta- • Cet équipement ne doit pas être utilisé par des enfants ou des tion avant de travailler sur le système ou autour de celui-ci.
  • Página 11: Placement Dans Le Bassin

    INSTALLATION Préparation de l’assemblage Préparation de l’assemblage Retirez l’emballage de l’ensemble, en conservant la boîte et les instructions de montage. 2. Lisez attentivement le manuel d’utilisation de la pompe pour vous familiariser avec son fonctionne- ment. 3. Modèles avec refoulement télescopique (515801, 515835) : Une fois l’ancien assemblage retiré, mesurez la distance entre le fond du refoulement et le fond du couvercle (dimension A), puis ajustez le refoulement du nouvel assemblage à...
  • Página 12: Pièces Et Dimensions De Remplacement

    PIÈCES ET DIMENSIONS DE REMPLACEMENT PIÈCES ET DIMENSIONS DE REMPLACEMENT Câblage de flotteur Câblage de flotteur de pompe d'alarme Câblage de pompe 16.75” Câblage de pompe 6.50–7.00” Collier de tuyauterie 8.00–8.50” Attache A-N448 Référenc Article Description Quantité Article Dimensions 515861 Pompe IGP-A231-20 Pour les modèles à...

Este manual también es adecuado para:

Igp-a-rfkIgphr-a-rfk

Tabla de contenido