INSTRUCTION SHEET
IGP Series Retrofit Kits
IGP-A-RFK and IGPHR-A-RFK grinder pump kits are direct, simplex replacements for existing positive
displacement systems.
These kits offer:
•
Fast, simple, easy installation
•
Epoxy-coated steel cover
•
Water-tight junction box for ease of installation and servicing
•
1-1/4" cast iron anti-siphon/check valve
•
1-1/4" NPT (SST) piping
•
Adjustable alarm float switch preset at factory
•
2 HP, 3450 rpm, high starting torque, automatic grinder pump with mechanical float switch
•
Tight cutting clearances for superior cutting action, grinding 414,000 cuts per minute
•
Quick disconnect plug in either square or round format
•
Rigid construction for ease of handling
•
Telescoping discharge (Models 515801, 515835)
Please examine your pump carefully to ensure that no damage occurred during shipment. If damage
has occurred, please contact the place of purchase. They will assist you in replacement or repair, if
required.
This product is covered by a Limited Warranty for a period of 24 months from the date of original pur-
chase by the consumer. For complete warranty information, refer to www.franklinengineered.com; or,
call Technical Support for a printed copy.
Specifications
Model
Phase
IGP-A-RFK
IGPHR-A-RFK
BEFORE GETTING STARTED
This equipment should be installed and serviced by technically
qualified personnel who are familiar with the correct selection
and use of appropriate tools, equipment, and procedures. Failure
to comply with national and local electrical and plumbing codes
and within FPS recommendations may result in electrical shock or
fire hazard, unsatisfactory performance, or equipment failure.
Know the product's application, limitations, and potential haz-
ards. Read and follow instructions carefully to avoid injury and
property damage. Do not disassemble or repair unit unless
described in this manual.
Refer to product data plate(s) for additional precautions, operat-
ing instructions and specifications.
Failure to follow installation or operation procedures and all
applicable codes may result in the following hazards:
Volts
Hz
1
208-230
60
1
208-230
60
Amps
Breaker Size
Watts
13.9
20
3200
16
20
3600
Risk of death, personal injury, or
property damage due to explosion, fire,
or electric shock.
•
Do not use to pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc.
•
Do not use in explosive atmospheres or hazardous locations
as classified by the NEC, ANSI/NFPA70.
•
Do not handle a pump or pump motor with wet hands or
when standing on a wet or damp surface, or in water.
•
When a pump is in its application, do not touch the motor,
pipes, or water until the unit is electrically disconnected.
•
If the power disconnect is out of sight, lock it in the open
position and tag it to prevent unexpected application of
power.
•
If the disconnect panel is not accessible, or under flooded
conditions, contact the electric company to stop service.
English
EN
HP
Shut Off
2
130 ft (39.6 m)
2
200 ft (61 m)