5. Maintenance**

Airmax
®
Aeration Systems are designed for low-maintenance and require minimal
scheduled maintenance. Cabinet inlets and outlets should be kept free of debris and
weed growth allowing normal ventilation.
• Always unplug system before performing any maintenance or troubleshooting.
• Always unplug system and refer servicing to a qualified electrician when: cord is
damaged or frayed, compressor, power control, compressor fan, or other electrical
components are producing unusual noises or odors.
• Always use parts that are supplied or approved by Airmax
result in poor performance and could create a hazardous situation.
**Local environmental conditions may require more frequent maintenance.
WARNING: Compressors are equipped with a thermal overload switch. If temperature
becomes high enough to trip the overload, the compressor will shut down. It will then
automatically start up when temperature decreases as long as power is applied.

6. Troubleshooting

IF COMPRESSOR IS NOT OPERATING:
ISSUE
Cabinet fan is not running.
Cabinet fan is running.
IF COMPRESSOR IS OPERATING:
ISSUE
No bubbles at any diffusers.
No bubbles at some diffuser plates.
Large rolling bubbles instead of fine
bubbles at surface above one or more
diffuser plates.
Compressor stops working for periods of
time, then restarts.
Compressor shakes erratically and is
making loud noises.
, Inc. Use of other parts may
®
CHECK
Option 1: GFCI circuit tripped.
Option 2: GFCI circuit not tripped.
Compressor is plugged in?
CHECK
Option 1: No air leaks are audible in
cabinet. Compressor running
louder and possible excessive
vibration.
Option 2: Compressor operating normally
or making unusual noises.
Exhibits reduced pressure and/
or air flow.
Option 1: Check for leaks at all
connections in line and in
cabinet. If none are audible,
carefully spray SMALL amount
of soapy water onto connections
and look for bubbles.
Option 2: Are all flow control valves in
compressor wide open?
Option 3: Valves in cabinet are properly
"balanced" and no leaks
are evident.
Inspect each diffuser plate for malfunction.
Inspect cooling fan for proper function.
Option 1: Check for low voltage while
compressor is running.
Option 2: Check for clogged air filter.
EVERY 3-6 MONTHS - Air Filter: Clean/replace air filter. Cooling Fan: Check to ensure cooling fan is
operating. Hot air should be pulled from cabinet, not cool air blowing in.
EVERY 12 MONTHS - Membrane Sticks: Purge membrane sticks. For SW20 & SW40, while compressor
is running, shut off all air flow valves except one, forcing all air to one diffuser plate for 10 seconds. Repeat for
each plate.
EVERY 6-12 MONTHS - Maintenance Kit: It is recommended to install a maintenance kit every 6-12
months to ensure optimum performance.
LIKELY CAUSE
Damage to electrical cord or low voltage from
power supply.
GFCI malfunction.
LIKELY CAUSE
Compressor air filter is dirty/clogged.
Compressor needs diaphragm maintenance kit
and possibly new air filter.
Vibration loosened connection or cracked fitting.
Improper "balancing" of diffusers.
Compressor beginning to lose compression and
needs diaphragm maintenance kit.
Diffuser membrane damaged, diffuser plate fitting
broken or diffuser plate is flipped over.
Compressor over-heating due to bad cooling fan.
Gauge of supply wires to circuit possibly undersized
or cabinet is plugged into extension cord.
Air filter in need of replacement.
Watch the Maintenance Kit
How-To Video at
airmaxeco.com/ShallowWaterSeries
CORRECTION
®
Contact Airmax
or local dealer for electrical
troubleshooting assistance.
®
Contact Airmax
or local dealer for repair/replacement.
CORRECTION
Clean or replace air filter. NEVER re-install wet filter.
®
Contact Airmax
or local dealer with specifications for
maintenance kit. Clean or replace air filter. NEVER
re-install wet filter.
Tighten loose connection or replace cracked fitting
as necessary.
Adjust air flow valves on manifold in cabinet until all
diffusersoperate properly. See Section 4. System
Installation for more information.
®
Contact Airmax
or local dealer with compressor
specifications for maintenance kit.
®
Contact Airmax
or local dealer for repair/replacement.
®
Contact Airmax
or local dealer for fan replacement. If
possible, leave top of cabinet open for cooling. Otherwise,
unplug system until fan is replaced.
If gauge of circuit wiring is incorrect, have electrician
replace. NEVER use extension cord to operate system
for continual use.
Clean or replace air filter. NEVER re-install wet filter.
ENGLISH
5