TRANSFORMATEUR
GROUPE
FUSIBLES
F1
TRS
160mA
F2
SLR
250mA
F3
ENG
4A
F4
24V
500mA
BORNES
SORTABLES
0-1-2
LIGNE MONOPHASÉE 230 Vca
11-12
CLIGNOTANT
13-23
CONTACT AUXILIAIRE
18-19
24 Vca PHOTOCELLULE
14-15
CONTACT AUXILIAIRE 24Vca MAXI.
300mA
7
CONTACT NF STOP
8
COMMUN GND BOUTONS-POUSS.
9
CONTACT NO START
43
CONTACT NO START PIETON
8-10
LAMPE-TEMOIN 24Vca - 3W
PROGRAMMES ET FONCTIONS
DIP
FONCTION
1
2
SERVICE
OFF
OFF
AUTOTEST
OFF
ON
PERSONNE PRESENTE
ON
OFF
SEMI-AUTOMATIQUE
ON
ON
AUTOMATIQUE
3
SEQUENCE AUX COMMANDES START
OFF
OUVERTURE. ; SEULEMENT AVEC FCO FERMETURE; EN
FERMETURE, ARRET ET OUVERTURE ( PROG. IMMEUBLE ).
ON
OUVERTURE, STOP, FERMETURE, STOP, OUVERTURE......
4
PRE CLIGNOTEMENT
OFF
EXCLU
ON
INCLU ( 2.5" AVANT CHAQUE PHASE DE MOUVEMENT )
5
CELLULE PHOTO-ELECTRIQUE
OFF
INTERVIENT UNIQUEMENT EN FERMETURE EN ARRETANT
ET EN OUVRANT JUSQU'A FCO.
ON
AUSSI BIEN EN OUVERTURE QU'EN FERMETURE, ARRETE
ET, UNIQUEMENT SI LIBEREE, OUVRE A NOUVEAU
6
REVERSER
OFF
EXCLU
ON
INCLU
7
INVERSION DU SENS DE MARCHE
OFF
MARCHE DIRECTE
ON
MARCHE INVERSEE
8
NON UTILISE
OFF
MAINTENIR NECESSAIREMENT EN OFF
APPAREILLAGE ELECTRONIQUE ASX03I
GROUPE
RELAIS
F1
F2
F3
F4
LED LGT
Après une modification de configuration des
dip-switches, mémoriser la modification
COMMANDES ET CONTROLES
TRIMMER REGL. DU
TEMPS DE PAUSE
( 2 ÷ 120" )
LED LGT
- 12 -
MICROPROCESSEUR
MICRO INTERR.
DE PROGRAMM.
CONNECTEUR
RADIO
TRIMMERS
CONNECTEUR
REVERSER
LEDS DE CONTROLE
ATTENTION
par RESET.
DIP-SWITCH DE
PROGRAMMATION
TRIMMER REGL. DU
TEMPS DE SERVICE
( 2 ÷ 80" )
LED CONTROLE
FCA
FIN DE COURSE OUVERTURE
FCC
FIN DE COURSE FERMETURE
LUX
CELLULE PHOTOELECTRIQUE
STP
POUSSOIR STOP
RUN
POUSSOIR START
PAR
POUSSOIR START PIETON
REV
REVERSER
TOUCHE
RESET