b. Test Stations:
I. Test all stations – tests all active stations
(with a run time), according to the time
duration you've set.
II. Run single station – choose the station
you would like to test, then set the duration.
The stations will run sequentially based on
duration set.
III. Run program – will run program selected.
10. DC Latching Solenoid start-up procedure
a. Because some DC latching solenoids will default to the latched (open) position
before installation, the valve will appear stuck open.
b. It is necessary to energize all zones to unlatch the coil and close the valve,
should this occur.
c. From the Manual Operation Screen, TEST ALL STATIONS for 2 seconds each.
This should unlatch the coil and close the valve in each station, should the
plunger be latched magnetically prior to installation.
IF YOU FORGET THE SECURITY KEY: If you forget the security key or passcode,
you must disconnect the battery and reset the module by making a short circuit on
the battery connections for 10 seconds, then reconnet the battery (see illustration
below). Then press "Add a Module" on the home screen and follow the instructions
above to assign a security key.
Make contact on the battery terminals
for 10 seconds with something metallic.
Reconnect and insert the battery.