Safety Features; Audible Warning Of System Failure; Flow Limiting Orifice; Hours Run Meter - Parker BAC-4015 Guía De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

3.3 Safety Features

The following safety features are incorporated as standard in the BAC-4015 and must not be disconnected, removed, or bypassed in any
manner.

3.3.1 Audible warning of system failure

If the BAC-4015 is depressurised without the operator's knowledge (e.g. compressor failure or system pressure loss), a warning whistle will
sound when the pressure drops to below 4 bar g (58 psi g) (minimum operating pressure).
The fault must be identified and rectified before the equipment is used again.

3.3.2 Flow limiting orifice

This device limits the outlet flow rate proportionally to the line pressure thus ensuring that the volumetric air flow rate of the BAC-4015 is not
exceeded. The flow limiting orifice is located immediately after the outlet pressure regulator.

3.3.3 Hours run meter

The meter gives a visual indication of the operating hours of the BAC-4015.
When pressure to the purifier is established an internal pressure switch closes, operating the meter. The decimal point on the display blinks
when the meter is working. When pressure is removed from the Breathing Air Purifier the meter stops (see 'Hours Run Meter Schematic').
The hours run meter is battery operated with an expected 10 year life (not guaranteed). A knock out panel is provided on the facia of the cabinet
to accept the meter. An internal rail is also located behind this panel to house the pressure switch. Air supply to this pressure switch should be
taken from the cam timer motor inlet via a 'Y' connector (not supplied).
PRESSURE SWITCH
3
1
2
TO AIR MONITOR INLET VIA Y-CONECTOR
2 (N)
1 (L)
HOURS RUN METER
7

Publicidad

Tabla de contenido
loading

Tabla de contenido