KX15DQ
15m Digital PIR Detector
EN50131-2-2:2008
Security Grade (SG) 2
EN50131-1:2006+A1:2009
Environmental Class (EC) II
PD6662:2010
E N G L I S H
(Diagram references)
1
A
D
G
Printed Circuit Board (PCB)
Lens holder
Casing screw
B
E
LED light pipe / di user
PCB screw
C
F
Lens
Captive nut
2
PCB con guration (Including PIR sensitivity)
3 3
Mounting Options
3 4
EOL Resistor Headers: The KX15DQ has 2 sets of header pins (as shown). These
headers are used to select the End of Line resistance for EOL wiring applications.
NOTE: If EOL wiring is not used, leave the headers OFF.
3 5
Remote LED Enable: This is used when the LED is disabled via the LED ON/OFF
link. To enable this feature the LED terminal needs to be connected to an output
on the control panel. When the system is in walk test mode the output should
be at 0v. For Pyronix panels the output would usually be programmed as
'Remote LED enable'.
3 6
A
N/C - Normally Closed Wiring
(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)
B
PCX DEOL Wiring
(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)
C
EURO DEOL Wiring
(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)
D
Generic Control Panel (shows resistor locations)
E
2x Double End of Line Detectors to One Input
(SEE CONTROL PANEL INSTRUCTIONS)
3 7
Powering Up: When the detector is rst powered up, it will run through a self-test
routine (indicated by the ashing blue LED). Once the LED goes out the detector
is ready to use.
3 9
3 8
The 15m Volumetric Lens.
Dimensions and Weight
Technical Specification
Model: KX15DQ
Colour: White
LED Colour: Blue
Casing: 3mm ABS, 0.4mm HDPE in lens area
Detection Method: Digital Quad Signal Processing
PIR Sensitivity: Auto (Default), High, Low
Temperature Compensation: Digital
Detection Range: 15m (13m by EN50131-2-2 & INCERT criteria)
Detection Speed: 0.3 - 3.0 m/s
Operating Voltage: 9 - 16V DC 13.8V DC typical
Current Consumption: 13mA @ 12V (Min), 16mA @12V (Max)
Relay Output: 50mA 60V DC, 42 VAC (RMS)
Contact Resistance: < 10 ohms
Mounting Height: 1.8 - 2.4m
Tamper Switch: 12V 50mA
Storage Temperature: -40
C to 80
C
o
o
Certi ed Operating Temperature: -10
o
C to 40
o
C
Nominal Working Temperature: -30
o
C to 70
o
C
Accessories: Wall and Ceiling brackets
Emissions: EN55022 Class B
Immunity: EN50130-4
Warranty
This product is sold subject to our standard warranty conditions and is warranted
against defects in workmanship for a period of ve years.
For further warranty information visit: www.pyronix.com/warranty
Product Warning Information
For electrical products sold within the European Community. At the end of the
electrical products life, it should not be disposed of with household waste. Please
recycle where facilities exist. Check with your Local Authority or retailer for recycling
advice in your country. The declaration of conformity may be consulted at
www.pyronix.com/product-compliance.php
This product is approved for use in the Residential,
Commercial and Light Industrial Environments.
 0845 6434 999 (UK). +44(0)1709 535 225
1
START
C
3
A
B
 customer.support@pyronix.com
 www.pyronix.com
2
A
B
B
LED ON
E
f ) Back
Tamper
D
F
G
C
D
Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK
PCB
TAMPER
LED OFF
DEFAULT
PREDEFINITO
= =
AUTO HI
LOW AUTO
=
AUTO HI
LOW AUTO
=
AUTO HI
LOW AUTO
C3
A
ALARM
6K8, 5K6,
4K7, 2K2, 1K
TAMPER
5K6, 4K7, 2K2, 1K
PIR
AUTO
+
+
+
+
HIGH /
LOW
HIGH
+
+
+
+
D
LOW
The
®
+
+
+
+
3
EOL
B
C
RINS1039-8

Publicidad

loading

Resumen de contenidos para HIKVISION Pyronix KX15DQ

  • Página 1 START KX15DQ TAMPER 15m Digital PIR Detector ALARM 6K8, 5K6, EN50131-2-2:2008 Security Grade (SG) 2 4K7, 2K2, 1K EN50131-1:2006+A1:2009 LED ON LED OFF Environmental Class (EC) II PD6662:2010 E N G L I S H (Diagram references) Printed Circuit Board (PCB) Lens holder Casing screw TAMPER...
  • Página 2 ALARM: ALARM TAMPER ALARM TAMPER TAMPER: ALARM TAMPER ALARM TAMPER 6K8, 5K6, TAMPER ALARM Control Panel Output ALARM Control Panel Output 5K6, 4K7, ALARM (0v in walk test) (0v in walk test) 4K7, 2K2, CONTROL CONTROL 2K2, PANEL PANEL ALARM TAMPER ALARM TAMPER...
  • Página 3 KX15DQ KX15DQ KX15DQ KX15DQ Digitaler PIR-Melder (15 m) Digitale PIR-detector, 15 m Détecteur PIR numérique, portée 15 m Rilevatore PIR digitale 15 m EN50131-2-2:2008 EN50131-2-2:2008 Classe de sécurité (SG) 2 EN50131-2-2:2008 Sicherheitsstufe (SG) 2 Beveiligingsniveau 2 EN50131-2-2:2008 Grado di sicurezza (SG) 2 EN50131-1:2006+A1:2009 EN50131-1:2006+A1:2009 EN50131-1:2006+A1:2009...
  • Página 4 KX15DQ KX15DQ KX15DQ KX15DQ Detector PIR digital, 15 m Detetor PIR digital de 15 m Czujnik cyfrowy 15 m PIR EN50131-2-2:2008 EN50131-2-2:2008 Класс безопасности (SG) 2 EN50131-2-2:2008 Certificado Grado 2 Grau de segurança 2 EN50131-2-2:2008 Stopień bezpieczeństwa (SG) 2 EN50131-1:2006+A1:2009 EN50131-1:2006+A1:2009 EN50131-1:2006+A1:2009 EN50131-1:2006+A1:2009...