KX12DT-WE
Two Way Wireless 12m Dual Technology Detector
RINS1420-1
EN50131-2-4:2008
EN50131-5-3:2005+A1:2008
PD6662:2010
Security Grade 2
Environmental Class II
EN
References:
WIRELESS DEVICE CONTROL (LEARN WIRELESS DEVICES)
NOTE: From the powering up of the detector, and after learning,
there is a 10 minute timer that allows a walk test of the PIR and
Microwave (without having to access WALK TEST on the control
panel). This is a useful feature to set up the correct microwave
distance and the sensitivity. After this 10 minute timer the
detector will go back to its "sleep" state.
Input Learnt!
DIAGNOSTICS
CHANGE INPUTS (PROGRAM INPUTS)
Specification
Input Configuration
Type: Normally Closed.
Lens/Detection
RLNS074, 12m volumetric coverage, 30 zones, 7 planes, 85˚
Detection Speed: 0.3- 3.0m/s
Monting Height: Maximum 2.4m
Sensitivity: High or Low
Battery
Battery: 2 x 3.0V CR123A. Threshold: 2.5V +/- 5% at 25°C.
Life: Up to 2 Years
NOTE: IF ONE BATTERY NEEDS REPLACING, MAKE SURE YOU
REPLACE BOTH BATTERIES.
Wireless
Transmission Frequency: 868MHz, FM Transceiver Narrow Band
Transmission Method and Range: Fully encrypted rolling/1.6km free
space
Materials and Environment
Colour and Casing: White. 3mm ABS
Indication: LEDs (Signal, Battery, Alarm, Tamper)
Temperature Compensation: Advanced Automatic
Temperature: Storage:-20°C to 50°C. Certified:-10°C to 40°C.
Nominal:-10°C to 50°C
Dimensions (H x W x D): 117 x 69 x 59mm
Compatible with the Enforcer, PCX and EURO control panels
(EURO-ZEM32-WE/PCX-RIX32-WE only).
Do not partially or completely obscure the detectors field of vision
NOTE: The KX brackets are optional.
Battery Information
The batteries supplied have been chosen to provide long service life
whilst, for safety reasons, having limited output current.
The battery is protected on purchase by a piece of plastic that must be
removed for operation. When disposing of the product, the battery must
be removed and disposed of separately in accordance with the local
regulations.
Product Information
For electrical products sold within the European Community. At the end of the electrical products
life, it should not be disposed of with household waste. Please recycle where facilities exist. Check
with your Local Authority or retailer for recycling advice in your country.
To prevent possible damage to components, any static charge on your body needs to be eliminated
before touching the inside of the unit. This can be accomplished by touching some grounded/earthed
metallic conductor such as a radiator/pipework immediately before replacing the batteries.
Warranty
This product is sold subject to our standard warranty conditions and is warranted against defects in
workmanship for a period of two years (batteries excluded). In the interest of continuing care and
design, Pyronix Ltd reserves the right to amend specifications, without giving prior notice.
Please see the control panels programming manuals for further information.
0845 6434 999 (UK). +44(0)1709 535 225
LEARN
>5s
.
2.4m
0m
12m
12m
12m
customer.support@pyronix.com
Input Learnt!
CHANGE INPUTS?
Input
Input 01
Input Type [07]
Final Exit
Input Active In
www.pyronix.com
Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK
DIAGNOSTICS?
View Wireless
Device Status?
Signal Strength?
Inputs?
≤300s
3---------------
----------------
LEDs
LEDs
[01]
[ABCD]
WIRELESS DEVICE
CONTROL?
Control Inputs?
Learn Devices?
Input 01
Available
[01]
Learning
5s
0.25 - 2.5m/s
HIGH
LOW
0.25 - 2.5m/s