REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
WARNING
Keep flammable materials and vapors, such as gasoline,
away from dryer.
Place dryer at least 18" (46 cm) above the floor for a
garage installation.
Failure to do so can result in death, explosion, or fire.
• If the dryer is approved for installation in an
alcove or closet, it will be stated on a label on the
dryer back.
• The dryer MUST be vented to the outdoors. See
the EXHAUSTING THE DRYER section.
• Minimum clearance between dryer cabinet and
adjacent walls or other surfaces is:
0" either side
3" front
3" rear
• Minimum vertical space from dryer to overhead
shelves, cabinets, ceilings, etc., is 1" on top.
• Consideration must be given to provide adequate
clearance for installation and service.
• Closet doors must be louvered or otherwise
ventilated and have at least 60 square inches of
open area. If the closet contains both a washer
and a dryer, doors must contain a minimum of
120 square inches of open area.
NOTE: WHEN THE EXHAUST DUCT IS LOCATED IN
THE REAR OF THE DRYER, THE CONFIGURATION OF
THE DUCTING MAY REQUIRE GREATER THAN 3" OF
REAR CLEARANCE.

POWER CORDS:

GE strongly recommends the use of factory specified parts.
Select the power cord to fit your installation requirements.
Order on-line at GEApplianceParts.com, 24 hours a day or
by phone at 800.626.2002 during normal business hours.
Installation Instructions
- Explosion Hazard
MINIMUM CLEARANCE OTHER THAN
ALCOVE OR CLOSET INSTALLATION
Minimum clearance to combustible surfaces and
for air opening are: 0" both sides, 1" front and
3" rear. Consideration must be given to provide
adequate clearance for installation and service.
MOBILE OR MANUFACTURED HOME
INSTALLATION
• Installation must conform to the
MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24, PART 32–80 or
Standard CAN/CSA-Z240 MH, or, when such
standard is not applicable, with AMERICAN
NATIONAL STANDARD FOR MOBILE HOME,
ANSI/NFPA NO. 501B.
• The dryer MUST be vented to the outdoors. The
exhaust vent must be securely fastened to a
non-combustible portion of the mobile home.
• The vent MUST NOT be terminated beneath a
mobile or manufactured home.
• The vent duct material MUST BE METAL.
• KIT 14-D346-33 MUST be used to attach the dryer
securely to the structure.
• The vent MUST NOT be connected to any other
duct, vent or chimney.
• Do not use sheet metal screws or other
fastening devices which extend into the interior
of the exhaust vent.
• Provide an opening with a free area of at least
25 square inches for introduction of outside air
into the dryer room.
• See the sections for electrical connection
information.
Part Number
Type
WX9X2
3-Prong
WX9X3
3-Prong
WX9X4
3-Prong
WX9X18
4-Prong
WX9X19
4-Prong
WX9X20
4-Prong
3
Length
Amperage
4 Feet
30
5 Feet
30
6 Feet
30
4 Feet
30
5 Feet
30
6 Feet
30