• The machine will restart when the bucket is
restored in its correct position.
NOTES:
• When you remove the bucket, do not touch
any parts inside of the unit. Doing so may
damage the product.
• Be sure to push the bucket gently all the
way into the unit. Banging the bucket
against anything or failing to push it in
securely may cause the unit not to operate.
• When you remove the bucket, if some
water spills in the unit you must dry it
before replacing the bucket.
• When the unit is on, if the bucket is
removed, the compressor and the fan will
turn off, the unit will beep 8 times, and the
digital display will show P2.
• When the unit is off, if the bucket is
removed, the unit will beep 8 times and the
digital display will show P2.
2. Continuous draining
• Water can be automatically emptied into
a floor drain by attaching a water hose
(inner diameter 5/16", not included) to a
female threaded end (inner diameter 1",
not included)
• Remove the plastic cover from the back
drain outlet of the unit and set aside, then
insert the drain hose through the drain
outlet of the unit and lead the drain hose to
the floor drain or a suitable drainage facility
(see Fig. 3 and Fig. 4).
• When you remove the plastic cover, if there
is some water in the back drain outlet of
the unit, you must dry it. Make sure the hose is secure so there are no leaks, and that the end of
the hose is level with or lower than the unit to let the water flow smoothly.
• Direct the hose toward the drain, making sure that there are no kinks that will stop the water flowing.
• Select the desired humidity setting and fan speed on the unit, and the continuous draining will start.
NOTE: When the continuous draining feature is not being used, remove the drain hose from the
outlet, and dry any residual water in the continuous drain hose outlet.

SAFETY PRECAUTIONS

• Do not allow children to play with or on the appliance.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
• The appliance shall be installed in accordance with national wiring regulations.
www.Hydrofarm.com
6
INSTRUCTIONS
Pull out the bucket a little.
Hold both sides of the bucket with even
strength, and pull it out from the unit.
Fig. 2
Pour the water out.
Fig. 3
Remove the
plastic cover
by counter-clockwise rotation.
Fig. 4
Drain hose
Fig. 1