Descargar Imprimir esta página

Premium PES600A Manual De Uso Y Cuidado página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION
Warning!
All electrical work should be carried out by a suitably qualified and authorised electrician.
No alterations or wilful changes in the electric-ity supply should be carried out.
Fitting guidelines
The oven is manufactured to work with three-phase alternating current (220V-240V/50Hz).
The connection diagram is also found on the cover of the connection box. Remem-ber that the
connection wire should match the connection type and the power rating of the oven.
The connection cable must be secured in a strain-relief clamp.
Warning!
Remember to connect the safety circuit to the
connection box terminal marked with
ctrictity supply for the oven must have a safety
switch which enables the power to be cut off in
case of emergency.The distance between the
working contacts of the safety switch must be at
least 3 mm.Before connecting the oven to the
power supply it is important to read the informa-
tion on the data plate and the connection diagram.
CONNECTION DIAGRAM
Voltage of heating elements 220V~240V
Caution! In the event of any connection the safetywire
must be connected to the
1
For 220V~240V earthed one-phase connection,
bridges connect 1-2 terminals and 4-5 terminals,
safety wire to
.The ele-
Caution!
PE terminal
8
2
1
1
2
3
5
4
1
2
3
L1
5
4
PE
N

Publicidad

loading