Bridge
Member
Screw
Correct
Top View
#8-18 x 1/2"
16. Install the Bridge Members
NOTE: The water dam on the bridge member should be toward the outside of the shower.
Slide the upper and lower bridge members onto the connectors.
Secure the bridge members to the side fixed panels using a #8-18 x 1/2" self-drilling screws.
17. Secure the Side Fixed Panels
NOTE: Perform the procedures below from inside the shower.
NOTICE: Do not overtighten the screws. If overtightened, the screws will cause the opposite side of the
wall jamb to bow outward.
Tighten the screws.
Ensure the wall jamb is still plumb. If adjustment is needed, loosen the screws and slide the panel
until plumb.
Repeat with the second side fixed panel.
Sterling
Screw
Screw
Screw
19
Top
Inside of
Bridge
Shower
Member
Bottom
1100676-2-F
Water
Dam
Outside of
Shower