DUCTWORK, WIRING LOCATIONS

Determine the exact location of the insert
sleeve. Mark the exact centerline location.
The ceiling structure must be capable of
supporting the weight of the insert sleeve
(approximately 100 pounds), the canopy
itself, any mounting hardware and any
inadvertent user contact loads.
• Measure from the top of the cooking
surface to the bottom edge of the insert
sleeve. Add insert sleeve installation height.
Mark that location.
• Use a level to draw a straight horizontal
pencil line on the wall.
NOTE: House duct should drop to 11-1/2"
above bottom edge of insert sleeve.
Location of house duct is important
because it must align with vent of damper
plate assembly.
Ceiling ducting:
If ductwork will vent straight up to the ceiling:
• Use a level to draw a centerline straight up
to the ceiling.
• On the ceiling, measure 5-1/2" from the
back wall to the centerline of an
8-1/2" hole.
Rear Wall Ducting: (See important note.)
If ductwork will vent to the rear:
• Use a level to draw a centerline straight
up to the ceiling.
• Measure at least 22-1/2" above the pencil
line that indicates the bottom installation
height, to the centerline of an 8-1/2" dia.
duct hole. (Hole may be elongated for duct
elbow.)
HOUSE WIRING LOCATION:
• The junction box is located inside the top
left side of the hood.
• Wiring should enter the back wall at
least 15" above the bottom of the insert
sleeve, and within 6" of the left side of the
centerline.
Wall Installation Preparation
22-1/2" above
pencil line
indicating
bottom of hood
4" liner height
*30" Minimum required
*36" Maximum
recommended
installation height from
cooking surface
36" from
floor to
countertop
* Always refer to the cooktop or range installation instructions
for product-specific clearances.
IMPORTANT NOTE: If you are planning to vent through the rear
wall, and the ceiling height is 8 ft., the maximum installation
height is 33" above the cooking surface.
5-1/2" from
rear wall to
centerline
11-1/2"
Side view
Illustrations not to scale
13
22-1/2" above
pencil line
indicating
11-1/2"
bottom of hood
4" liner height
*30" Minimum required
*36" Maximum
recommended
installation height from
cooking surface
36" from
floor to
countertop
Front view