inStAllAtiOn
Continued
Installation must include an equipment shut-
off valve, union, and plugged 1/8" NPT tap.
Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from log
set (see Figure 3).
IMPORTANT: Install equipment shutoff valve
in an accessible location. The equipment
shutoff valve is for turning on or shutting off
the gas to the appliance.
Check your building codes for any special
requirements for locating equipment shutoff
valve to appliance.
Apply pipe joint sealant lightly to male NPT
threads (not required on flared fittings). This
will prevent excess sealant from going into
pipe. Excess sealant in pipe could result in a
clogged burner orifice.
WARNING: Use pipe joint
sealant that is resistant to liquid
petroleum (LP) gas.
Approved Flexible Gas Hose
(if allowed by local codes)
CSA Design-Certified
Equipment Shutoff Valve*
3"
(7.62 cm)
Min.
Cap Pipe
Sediment Trap (Optional for
Propane/LP Installation)
Figure 3 - Gas Connection
* Purchase the optional CSA design-certified
equipment shutoff valve from your dealer.
** Minimum inlet pressure for purpose of input
adjustment.
4
Natural Gas
From Gas Meter
(5" W.C.** to 10.5"
W.C. Pressure)
Propane/LP
From External
Regulator
(11" W.C.** to 14"
W.C. Pressure)
Tee
Nipple Joint
www.desatech.com
We recommend that you install a sediment
trap in supply line as shown in Figure 3.
Locate sediment trap where it is within reach
for cleaning. Install in piping system between
fuel supply and appliance. Locate sediment
trap where trapped matter is not likely to
freeze. A sediment trap traps moisture and
contaminants. This keeps them from going
into log set controls. If sediment trap is not
installed or is installed wrong, log set may
not run properly.
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping
and connections for leaks after
installing or servicing. Correct
all leaks at once.
WARNING: Never use an
open flame to check for a leak.
Apply a noncorrosive leak detec-
tion fluid to all joints. Bubbles
forming show a leak. Correct all
leaks at once.
PRESSURE TESTING GAS SUPPLy
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1. Disconnect log set and its individual equip-
ment shutoff valve from gas supply piping
system.
2. Cap off open end of gas pipe where equip-
ment shutoff valve was connected.
3. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve
located on or near gas meter for natural gas,
or using compressed air.
4. Check all joints of gas supply piping system.
Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect log set and equipment shutoff