4.1 Polarity of the inputs
4.2 Switching on the 30 Hz filter (INP A)
4.3 Multiplying factor (totaliser)
4.4 Dividing factor ( totaliser)
4.5 Decimal point (totaliser)
* where bounce occurs, e.g. with contacts
npn: switching for 0 V
pnp: switching for +U B
The filter provides input
damping*
30 Hz filter off (f max )
30 Hzfilter on
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0" is not accepted!
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0" is not accepted!
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0
no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
4.6 RESET-Mode (totaliser)
4.7 Multiplying factor (frequency meter)
4.8 Dividing factor (frequency meter)
4.9 Decimal point (frequency meter)
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via
the RESET input
only manual reset via the
red RESET key
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0" is not accepted!
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0" is not accepted!
The decimal point defines
the resolution in the
selected measuring range
1/min or 1/sec
0
no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
3