Decimal Point; Operating Mode - Crouzet CTR24L-2515 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4.3 Input mode (time meter)

4.4 Operating mode

*0, 0.1, 0.01, 0.001 means: time measurement in
0, 0.1, 0.01, 0.001 time units
10
Start/Stop via Inp B.
Counting while Inp B
(Gate) not active or open
Start/Stop via Inp B.
Counting while Inp B (Gate)
active (High level with
pnp; Low level with npn)
Count Start/Stop via INP B
(LOW-HIGH edge with
pnp; HIGH-LOW edge
with npn). Every active
edge changes the counter
status.
Count start via INP A,
stop via INP B. (LOW-
HIGH edge with pnp;
HIGH-LOW edge with
npn)
Time unit: seconds (accu-
racy depending on posi-
tion of the decimal point*)
Time unit: minutes (accu-
racy depending on posi-
tion of the decimal point*)
Time unit: hours (accuracy
depending on position of
the decimal point*)
Time units:
Hours:Minutes:Seconds
(decimal point setting is
ignored)

4.5 Decimal point

4.6 RESET mode (time meter 1)
4.7 RESET mode (time meter 2)
The decimal point defines
the resolution of the pro-
grammed time unit.
0
1
0.0
1/10
(0,1)
0.00
1/100 (0,01)
0.000 1/1000 (0,001)
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via
the RESET input
only manual reset via the
red RESET key
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key

Publicidad

Tabla de contenido
loading

Tabla de contenido